Download Print this page

Toshiba RBC-ASCU11-UL Installation Manual page 2

Compact wired remote controller

Advertisement

How to install the remote controller
■ Install the remote controller on the wall
Rear case
Remote controller
body
1. Insert a slot-type screwdriver or the like into
the groove on the lower side of the remote
controller body, and twist it to remove the
rear cover.
2. Cut the plastic stud in the accessory to a
suitable length for filling the gap between
the rear cover of the remote controller and
the studs of the bottom case, and then use
the M4 screws in the accessory to fix the
rear cover to the bottom case through the
stud.
Note 1: Do not tighten the screws too
tightly, otherwise the rear cover will deform.
Note 2: When using studs to fill the gap,
make sure that the rear cover height is
uniform to prevent deformation.
3. Connect the remote controller cable (2-
core) to the cable of the remote controller
body. Confirm the terminal number of
indoor unit and connect the remote
controller cable correctly. (The remote
controller may be damaged if connecting
the power supply of indoor unit.)
4. Hang the remote controller body to the
hook on the rear cover and fix it in place.
Note 3: Allow at least 1.2in (30 mm) of
space around the remote control.
DIP switch setup
The dial switch is located on the circuit board
of remote controller. When switching, remove
the rear cover. But be sure to turn off the air
conditioner power first.
Wall
Wiring slot
Screws
0.16"×0.98"
(M4×25mm)
DIP switch
DIP
1
switch
Main
remote
Setting
controller
Backlight
item
/ Sub
remote
controller
Sub
On
remote
controller
Main
Off
remote
controller
■ Main remote controller /Sub remote controller: 1
Use DIP switch 1 to set the main/sub remote
controller.
To use the remote controller as a sub remote
controller, slide the switch to the ON position.
To use the remote controller as a main remote
controller, slide the switch to the OFF position.
* For details, please refer to "Multiple Remote
Controller Installation Requirements."
■ Turn off LCD backlight: 2
Use DIP switch 2 to turn off the LCD backlight.
Turn off the backlight when the switch is turned
on, and turn on when the switch is turned off.
■ Temperature setting as unit of 2°F: 3
You can use DIP switch 3 to change the display
unit of temperature setting.
The unit is set to 2°F when the switch is turned
on, and the unit is set to 1°F when the switch is
turned off.
■ Remote controller sensor: 4
Use DIP switch 4 to set the remote controller
sensor. If to use the temperature sensor of the
remote controller, slide the switch to the ON
position.
If to use the temperature sensor of indoor unit,
slide the switch to the OFF position.
* For detailed information, please see
"Switching Temperature Sensor."
■ On/Off button setting: 5
Use DIP switch 5 to change the operation
mode of ON/OFF button to long press (approx.
4 seconds or more).
-2-
(Factory default)
2
3
4
Remote
Temperature
On/Off
controller
setting
button
sensor
Long
Off
2°F
On
press
Short
On
1°F
Off
press
5
6
Operation
indicator
lamp
Dim
Bright

Advertisement