Download Print this page

Sealey LED130S Instructions page 2

Floodlight with bracket and pir sensor

Advertisement

4.2.
sensor
the sensor may be angled independently of the light. Mounted at
approximately 2.5m above the ground the sensor will have approx 12m
range (fig 3) with a 120º spread (fig 4)
4.2.1 the sensor range can be reduced or optically adapted to local
conditions by adjusting the sensor angle accordingly.
4.2.2 further adjustment may be made by tuning the three switches located
on the underside of the sensor as follows: (refer to figure 5).
switch 1. sensitivity. the sensor range will vary with temperature and
factors such as passing cars, shade from large trees etc. During cold
weather the sensor range will be greater than when hot in summer
temperatures. for example during hot weather the forward detection
range could fall from 12 to 6m and as such the sensor should be
checked and adjusted. note: the sensitivity factor is far greater when
an object passes across the detection area (fig 4.A) than when an object
approaches towards the detector (B).
switch 2. time adjuster: to adjust the amount of time the light will stay
on when activated. Minimum is 6 seconds, maximum is 20 minutes.
switch 3. daylight adjustment: to adjust the sensor to come on in
accordance with the diminishing daylight. from 0 to 30 LuX.
fig 4.
recycle unwanted materials instead of disposing of them as waste.
All tools, accessories and packaging should be sorted, taken to a recycle centre and disposed of in a manner which is compatible
with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way. contact your local solid waste
authority for recycling information.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMportant: no liability is accepted for incorrect use of this product.
warrantY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
inforMation: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
fig 3.
4.3.
4.3.1 clean the light with a dry, dust-free cloth. Do not use solvents, or
4.3.2 if necessary clean the glass shield (when cold) with alcohol and a soft
4.3.3 Although weather proof the light must not be stored wet. should the unit
fig 5.
environmental protection.
sole Uk distributor, sealey group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
iP32 7Ar
Original Language Version
general
repairs must only be undertaken by a qualified electrician.
abrasives to clean the light.
cloth. if the glass is damaged, Do not use the light without the glass
shield.
become wet, unplug from mains, wipe dry and store accordingly.
Do not use the light without the weather seals intact.