Low-noise, industrial, ceramic shear icp accel, 500 mv/g, 0.17 to 10k hz, top exit, 10-ft integral cable, single point iso 17025 accredited calibration (20 pages)
Page 1
Model 2304-02A REACTION TORQUE SENSOR Installation and Operating Manual For assistance with the operation of this product,contact: PCB Load & Torque, Inc. Toll-free: 866-684-7107 24-hour SensorLine™: 716-684-0001 Fax: 248-888-8266 E-mail: LTInfo@pcbloadtorque.com Web: www.pcbLoadTorque.com...
Page 2
“Lifetime Warranty Plus” on all Platinum Stock Products number, which we use to reference any information you sold by PCB and through its limited warranties on all other have already provided and expedite the repair process. PCB Stock, Standard and Special products. Due to the...
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Gage Committee as revised in May 1960. wiring code is as follows: Reaction torque sensors manufactured by the Force- Torque Division of PCB are strain gage based measuring instruments suitable for a wide range of torque measurement applications. They are rigid structures with no moving parts and are typically mounted in a fixed position.
In addition, review data from manufacturers of fixtures and fasteners used in the sensors installation to determine if failure might occur due Figure 4 - Axis and Sense Nomenclature for PCB Reaction to these loads. Torque Sensors 3.0 MECHANICAL INSTALLATION The principal axis of a transducer is normally the axis.
2. Apply full-scale, N.I.S.T. traceable, utilized by PCB reaction torque sensors are typically mechanical input (or torque) to the transducer. calibrated using the shunt calibration technique. 3. Adjust the signal conditioner’s gain or span controls, as required, to obtain a full-scale...
Operation requires the connection of the sensor to a signal conditioner, then to a readout device (if signal conditioner does not have a display). Strain gage signal conditioners and cable assemblies are available from PCB. Operation with a Signal Conditioner The signal conditioner span and zero must be set before the torque sensor system can be used.
No output moments (extraneous loads), the errors due to them No power are present. PCB engineers can design the set-up to Loose or dirty connections eliminate or minimize these extraneous loads. Circuit opens or shorts However, if these extraneous loads are present, the Faulty or improper wiring...
Page 12
REACTION TORQUE SENSOR OPERATION MANUAL Caution should be observed to insure that liquids are not permitted to migrate into devices that are not hermetically sealed. Such devices should only be wiped with a damp cloth and never submerged or have liquids poured on them.
Page 13
Flange (M20 Bolts) Torsional Stiffness 53,900 klbf-in/radian 6090 kN-m/radian PCB Load & Torque Sensing Element Strain Gage Strain Gage A Division of PCB Piezotronics Housing Material(Sensor) Plated Steel Plated Steel 24350 Indoplex Circle Electrical Connector PT02E-10-6P PT02E-10-6P Farmington Hills, MI 48335 All specifications are at room temperature unless otherwise specified.
Page 14
PCB Load & Torque Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others without DESCRIPTION the written consent of PCB Load and Torque Inc. REDRAWN, REMOVED PIN OUT VIEW - 02.23.18, PTE...
Need help?
Do you have a question about the 2304-02A and is the answer not in the manual?
Questions and answers