4
Timer
5
Adjustment
Additional Functions
Forced shutdown function
If the machine keeps running for 15 hours without any operation, it will automatically
shut down.
Temperature sensor short circuit, open circuit protection function
No matter in what mode, the temperature sensor appears short circuit or open circuit,
digital screen displays "E1" or "E2" and constantly flicker, while any key operation is
invalid and the buzzer rings 10 times.
Safety protection
When power on, if the room temperature TH is above 50°C , machine will close all
outputs system, The digital screen will show "FF" and flash 1 time per second in 75 times,
press any key will not work, only plug off to stop the protection.
Tip-over switch
As a safety measure, the display area will show "P4" and unit will shut off automatically if
it is knocked over. Should this occur, simply turn the heater off and stand it back up to a
regular upright posit ion, then switch it back on.
ECO energy saving function
Select the ECO energy saving gear and set the temperature. The heater will adjust its
heating gear by comparison between the ambient temperature and set temperature.
Function description
• When the heater is turned on, press the TIMER key to
enter the timing stop state (within 0-12 hours), then
press the "+" key to increase the timing stop time,and
press the "-" key to decrease the timing stop time.
• Press "+" or "-" can set the temperature value or timer.
• In the ECO mode of the machine, press "+" or "-" can set
the temperature value, set the range of 5-35°C. When the
room temperature exceeds the set temperature at 2°C,
the machine stops working, and stay in the standby state.
• When the temperature is lower than the set
temperature, the machine starts to heat up again.
06