Battery Inverter for all situations Mounting Bracket BAT Wire Cover BMS, RS485 Com Wire Cover The GivEnergy AC Coupled Inverter works as a standalone energy storage system or alongside AC Terminals Cover solar, hydro, or wind-turbine to store excess Cover Screw energy.
The model and specifi cation of the AC Coupled Inverters’ nameplate match the order specifi cations If any damaged or missing parts are found, please contact GivEnergy on 01377 252 874 or email support@givenergy.co.uk immediately. Returns must be provided in original or equivalent packaging. The...
Safety Instructions Precautions Extra care and attention must be taken when installing and maintaining any GivEnergy equipment. It is very important for system safety and effi cient operation to use appropriate cables for battery The system is capable of retaining a high voltage, even when disconnected.
Page 5
STEP-BY-STEP INSTALLATION Wall thickness for mounting the inverter should be suitable for the weight of the equipment. Mount the inverter onto the mounting bracket. Place the wall mounting bracket horizontally onto the wall and mark the position of the bracket holes.
CLEARANCE AND MAINTENANCE CONNECTIONS OVERVIEW Space Clearance Item Item Name Battery DC Ring Terminals There must be adequate clearance around the inverter to allow for heat dissipation. The diagram USB Input below illustrates the space required around the inverter. EPS Connections AC Connections Battery and Meter communcations 300mm...
Page 7
This output must be protected as close to the inverter as possible, with a double pole 30mA RCD and overload protection rated at up to 20A. AC 3.0 - minimum 2.5mm² There are four approved methods to connect to the EPS, please refer to the EPS Connection Guide on our The recommended maximum cable length should not exceed 50m as the resistance of the cable will Knowledge Base for more information.
Page 8
FULL PROPERTY BACKUP Correct wiring of full property back-up with manual or automatic change over switch: Incorrect wiring of full property back-up with manual or automatic change over switch: New ‘Grid’ Consumer Unit New ‘Grid’ Consumer Unit PV Inverters PV Inverters Supply Supply Meter...
Page 9
CONNECTING THE BATTERY TO THE INVERTER Generation 2 battery only A DC MCB must be installed between the master battery and the inverter of Gen 1 batteries (not When connecting a Gen 1 inverter to a Gen 2 battery (9.5kWh), a ring terminal to all in one less than 100A), this will ensure the inverter can be safely disconnected during maintenance.
Page 10
The CT clamp that is connected to the mid approved meter must be installed around the live incoming supply to the property, with the arrow pointing in the direction of grid import, in order to monitor the complete consumption of the building. Ensure that the meter used is approved for use with GivEnergy equipment.
Page 11
If you are a fi rst time user, and you do not have an account or Engineer login, please consult your supplier to get this set up. To download a fully illustrated guide, please visit our Knowledge Base at www.givenergy.co.uk Shutdown Procedure Turn off...
To download a fully illustrated guide on connecting the inverter to the EPS, please visit our and be strong enough to support both the weight and the size of the inverter. Knowledge Base at www.givenergy.co.uk. Storing the Inverter Store the inverter in a dry place where ambient temperatures are always between -25ºC and +60ºC...
Page 13
MANUFACTURER WARRANTIES This inverter is covered by a 12-year warranty. Products Covered AC Coupled Inverter 3.0 AC Coupled Inverter 12 years 12 years Legal Disclaimer: This document is property of GivEnergy, reproduction is prohibited.