Table of Contents

Advertisement

Available languages

Available languages

Quick Links

PA-607
Instrucciones
Instructions
Nº de serie:
Serial No.:
Fabricante:
Manufacturer:
FENIX Stage, S.L.
Avda. de los Trabajadores, 24
Horno de Alcedo
46026 - Valencia (Spain)
Tel.: +34 96 125 08 55
export@fenixstage.com
www.fenixstage.com
www.audiovias.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PA-607 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fenix PA-607

  • Page 1 PA-607 Instrucciones Instructions Nº de serie: Serial No.: Fabricante: Manufacturer: FENIX Stage, S.L. Avda. de los Trabajadores, 24 Horno de Alcedo 46026 - Valencia (Spain) Tel.: +34 96 125 08 55 export@fenixstage.com www.fenixstage.com www.audiovias.com...
  • Page 2 www.audiovias.com...
  • Page 3 DECLARATION OF CONFORMITY FENIX STAGE, S.L. Address: Avda. de los Trabajadores, 24 - Horno de Alcedo - 46026 - Valencia (Spain) Phone: +34 96 125 08 55 VAT No.: ESB-91423046 We declare at our exclusive liability the conformity of the product: Name: LIFTING TOWER P.A.
  • Page 4: Table Of Contents

    ÍNDICE 1.- INTRODUCCIÓN 2.- DATOS GENERALES 2.1.- Datos técnicos 2.2.- Normativa de aplicación 3.- NORMAS DE SEGURIDAD 4.- INSTRUCCIONES DE USO 5.- RIESGOS ESPECÍFICOS 6.- SISTEMAS DE PREVENCIÓN INDEX 1.- INTRODUCTION 2.- GENERAL DATA 2.1.- Technical data 2.2.- Applicable regulations 3.- GENERAL SAFETY RULES 4.- HOW TO USE 5.- SPECIFIC RISKS...
  • Page 5: Introducción

    ESPAÑOL 1. INTRODUCCIÓN Descripción del equipo: La torre PA-607 ha sido diseñada para El presente manual de instrucciones ha sido levantar sistemas de sonido. realizado en conformidad con los requisitos de la Directiva de Máquinas CE 2006/42/EG Ha sido probada por personal capacitado y sus sucesivas modificaciones.
  • Page 6: Normas De Seguridad

    ESPAÑOL 3. NORMAS GENERALES DE SEGURIDAD - La torre PA es un elemento industrial diseñado para la elevación de cargas en sentido vertical, nunca se debe utilizar como plataforma estructural de personas. - Colocar la torre PA sólo en superficies duras y planas, verificando que está en posición vertical.
  • Page 7: Instrucciones De Uso

    ESPAÑOL 4. INSTRUCCIONES DE USO 6. Antes de proceder a izar la torre, en caso de utilizar un motor (Z), pasar la cadena 1. Montar la base de la torre. El truss (T1) (J) por el cabezal (T7) y asegurarlo con una y el ángulo (T2) con los conectores (A).
  • Page 8 ESPAÑOL www.audiovias.com...
  • Page 9: Riesgos Específicos

    ESPAÑOL 5. RIESGOS ESPECÍFICOS 6. SISTEMAS DE PREVENCIÓN Pérdida de estabilidad Sobre pérdida de estabilidad Si se coloca la torre sobre un terreno El mantenimiento de la estabilidad de la inclinado o sobre una superficie que no torre PA debe realizarse básicamente con las sea completamente lisa existe el riesgo de siguientes medidas: pérdida de estabilidad lo que daría lugar...
  • Page 10: Introduction

    Truss type: Reinforced squared 29x29. Fixation of tower sections to working height with safety pins. Equipment description: PA-607 tower has been designed to raise sound equipment. Tested by skilled personnel having passed all the operating, maximum load and dimension inspections.
  • Page 11: General Safety Rules

    ENGLISH 3. GENERAL SAFETY RULES - The ground support tower is an industrial element designed to raise loads vertically, it must never be used as a platform elevator for people. - Only place the ground support tower on firm flat grounds checking it is in vertical position. Do not use wedges or any strange elements to balance the ground-support tower.
  • Page 12: How To Use

    ENGLISH 4. HOW TO USE 6. Before rising the tower using a motor, pass the chain through the top and tie it up with 1. Assemble the base of the tower. The truss a shackle and sling to the truss. Thus, the (T1) and the truss-corner (T2) with the motor will help to raise the tower.
  • Page 13 ENGLISH 13 13 www.audiovias.com...
  • Page 14: Specific Risks

    ENGLISH 6. SPECIFIC RISKS 7. PREVENTION SYSTEMS Loss of stability About braking system failure If the tower is placed on a sloping ground or Equip with winch according to BGV D8 y a surface that is not completely flat, there is a 2006/42/CE directive.
  • Page 15 www.audiovias.com...
  • Page 16 1160 2950 1809 2x 2507 1413 3025 4151 1845 1052 1414 3114 3113 1790 1810 1790 1114 1110 AC-647 2508 1860 1308 3121 2520 1818 1800 3120 3112 1091 www.audiovias.com...
  • Page 17 1035 3112 3438 4109 3110 3112 1810 1091 2367 3111 2515 3113 1810 2516 1790 1091 4203 1028 2508 1810 1790 1302 3112 3044 1004 1305 2052 1305 3069 1128 4252 8605 3042 1021 1308 www.audiovias.com...
  • Page 18 NOTAS / NOTES www.audiovias.com...
  • Page 19 NOTAS / NOTES www.audiovias.com...
  • Page 20 FENIX Stage, S.L. Avda. de los Trabajadores, 24 Horno de Alcedo 46026 - Valencia (España) Tel.: +34 96 125 08 55 export@fenixstage.com www.fenixstage.com www.audiovias.com...