31 |
VT 4.10, VT 4.16, VT 4.25, VT 4.40, VX 4.10, VX 4.16, VX 4.25, VX 4.40
9

PRODUCT DATA SHEET

9.1

PRODUCT OVERVIEW

Example: VT 4.40
9.2

OPERATING PARAMETERS

Variant
Volume flow min.
Volume flow max.
Vacuum
Weight
Sound level min.
Sound level max.
Permissible ambient
temperature
Exhaust air temperature max.
Maximum installation height
Maximum humidity of the
intake air
Table 9.2: Operating parameters
VT 4.10
10 m³/h (50 Hz)
16 m³/h (50 Hz)
12 m³/h (60 Hz)
19 m³/h (60 Hz)
150 mbar (abs)
150 mbar (abs)
16 kg
60 dB(A) (50 Hz)
61 dB(A) (50 Hz)
62 dB(A) (60 Hz)
64 dB(A) (60 Hz)
5 - 45 °C
87 °C
800 m ü.NN.
800 m ü.NN.
90 %
VT 4.16
VT 4.25
25 m³/h (50 Hz)
30 m³/h (60 Hz)
150 mbar (abs)
22,5 kg
26 - 29 kg
62 dB(A) (50 Hz)
67 dB(A) (60 Hz)
5 - 45 °C
5 - 45 °C
93 °C
118 °C
800 m ü.NN.
90 %
90 %
VT 4.40
40 m³/h (50 Hz)
48 m³/h (60 Hz)
150 mbar (abs)
38 - 41 kg
67 dB(A) (50 Hz)
72 dB(A) (60 Hz)
5 - 45 °C
126 °C
800 m ü.NN.
90 %

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vt 4.16Vt 4.25Vt 4.40Vx 4.10Vx 4.16Vt 4.10 ... Show all

Table of Contents