5. Operation
SFC
DUOCARTSWITCH OFF
DUOCARTSWITCH SWITCH1
Automatic
1
Standby
The command "SFC" permits monitoring of the current
operating status by displaying the various parameters. Please
refer to the user manual of the interface adapter for
additional commands.
If the DuoCartSwitch is activated, you will be informed about
the quantity of methanol which is consumed by the operating
cartridge:
Example:
SFC>SFC
battery voltage 12.46V
output current 3.17A
operation time (charge mode) 1304.7h
operating state: auto on
operating mode: auto
cumulative output energy 218144.6Wh
no error
cartridge level above sensor or no sensor
(cartridge 1 consumed: 4.3 l / 1.1 US gal)
As soon as the fuel cell switches to the other fuel cartridge,
the level is reset to zero.
Deactivates the DuoCartSwitch.
Switch from fuel cartridge 2 to fuel cartridge 1. The level of
consumed litres is reset to zero.
The control panel can also be used to switch from fuel
cartridge 2 back to fuel cartridge 1. Press simultaneously the
buttons „reset" and >> .
ADVICE: If the DuoCartSwitch is disconnected and
reconnected, the DuoCartSwitch doesn't have to be
reactivated. However, the EFOY Pro needs to be reset to the
fuel cartridge 1 as described above.
The number 1 appears in the display of the control panel.
16