Page 2
Important information for consumers in the EU Disposal instructions for batteries and rechargeable batteries Every consumer is legally obliged to return all used batteries and rechargeable batteries according to the Battery Ordinance (Directive 2006/66/EC). Disposal in the household waste is prohibited. Since batteries and rechargeable batteries are also included in the delivery of products from our range, we would like to point out the following: Used batteries and rechargeable batteries do not belong in the...
Please observe that the careful installation of the wastewater treatment plant is very important for a good treatment performance. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 3 from 24...
Page 4
2 Overflow baffler 3 SB reactor 4 Outlet 5 Float valve 6 Air lift pump 7 Buffer tank 8 Intake area ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 4 from 24...
Mounting parts PUROO 1-16 PE ® Fabric hose DN16 clear 18 m coil Operating instructions PUROO ® Installation instructions PUROO ® ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 5 from 24...
Page 6
- The opening for the charging of the SB reactor (Ø > 50 mm) must be attached 25-30 cm below the discharge pipe (below H Wmin ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 6 from 24...
Page 7
- With longer or final decommissioning the plant is to be emptied completely and is to be cleaned. PUROO - Tank ® Sampling section (incl. suction hose) Lifting body AQUAswitch ® ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 7 from 24...
Page 8
(if required, lengthen pipe!) Baffler in the area of the edge of the tank Separation each 5 – 20 ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 8 from 24...
Page 9
[cm] The minimum partition wall height is 1.20 m. Intermediate measurements are to be interpolated. Feed- pipe Suction pipe ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 9 from 24...
Page 10
HWmin (Air lift pump OFF) Upper lip of suction pipe must be lower than HWmin! Connection of the flexi-hose ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 10 from 24...
Page 11
Rotate the bend near the bottom on the biological side in the direction of the outer wall (see markings diag. right). ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 11 from 24...
Page 12
(diag. right), that the upper edge lies 5 cm below the outlet (see page 9). ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 12 from 24...
Page 13
Thus it is ensured that the air hose does not hinder the function of the (diag. below left/right). ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 13 from 24...
Page 14
To lead and secure the above given line and hoses use the white cable clip which is fixed in the cone (marking diag. bottom). ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 14 from 24...
Page 15
The installation in the tank type Aplast is comparable with the installation of the system in Graf tanks. Two separate PUROO® versions (4/6 EW + 10 PE) are available for the three Aplast tank sizes. To connect the airlift to the PUROO tank, a step ®...
Page 16
This allows the aerator to be lowered and aligned easily from the tank opening. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 16 from 24...
Page 17
Following the drawing though of the air hose and the float lead the empty pipe is to be closed airtight using the plugs supplied (see diag. below) and, if required, additionally sealed using polyurethane foam or mortar! ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 17 from 24...
Page 18
The overflow (opening Ø 100 mm, with floating sludge protection) should be at the level of the treatment plant outlet. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 18 from 24...
Page 19
Installation in concrete half-chamber Cover with ventilation openings Outlet Pretreatment Inlet Opening for empty pipe to control cabinet (on site) ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 19 from 24...
Page 20
Installation Instructions PUROO ® Installation in PE two-chamber tank „Type A“ Inlet Outlet Pretreatment ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 20 from 24...
Page 21
Installation Instructions PUROO ® Installation in PP two-chamber tank „Type G“ Separate ventilation must be provided Inlet Outlet Pretreatment ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 21 from 24...
Page 22
Installation Instructions PUROO ® Installation in PE two-chamber tank „Type 1R T“ Cover with ventilation Pretreatment Outlet Inlet ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0276 / Status: 21.06.2023 / Page 22 from 24...
Need help?
Do you have a question about the PUROO and is the answer not in the manual?
Questions and answers