Advertisement

Quick Links

16 VM SG Iron and Stainless Steel Construction, All variants
Models
16VMSXXX
16VMLXXX
16VMNXXX
16VMDXXX
Read this manual carefully before installing, operating or servicing this equipment. It's the responsi-
bility of the employer to ensure this manual is read by the operator. Please preserve this manual.
This document is issued with Product Serial No
Operation and Maintenance Guide
16 V M
Descriptions
FOOT Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT
Variants
FACE Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT
Variants
NEMA Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT
Variants
IEC Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT
Variants

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 16VMS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Teryair 16VMS Series

  • Page 1 Operation and Maintenance Guide 16 V M 16 VM SG Iron and Stainless Steel Construction, All variants Models Descriptions FOOT Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT 16VMSXXX Variants FACE Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT 16VMLXXX Variants NEMA Model with Lube / Lube-Free, SG Iron / SS &...
  • Page 2: Table Of Contents

    Operation and Maintenance Guide 16 VM Air Motor Series Page 2 Table of Contents Nomenclature Technical Data Safety Instructions Installation Instructions Operating instructions Suggested Lubricants Troubleshooting Dis assembly and Re-assembly Exploded View for 16VM Air Motor Bill of Materials for 16VM Series (SG Iron) Bill of Materials for 16VM Series (SS316) Dimensional Data Repair Kits for 16VM Test Certificate Of Materials, Performance Eu Declaration Of Conformity Warranty Certificate FF-MM-372-REV - 02...
  • Page 3: Nomenclature

    Operation and Maintenance Guide 16 VM Air Motor Series Page 3 Nomenclature Lubricated or Material of Threading on Inlet Size Motor Type Mounting Lube-Free Construction and Outlet L - Face Type VM - Vane Type S- Foot Type A- Lubricated R- NPT PM - Piston Type L - SG Iron...
  • Page 4: Safety Instructions

    Do Not temp. Class T6 (85°C). dis-assemble in explosive atmosphere. Caution i. EN / ISO 80079-36 : 2016 : Explosive Use only genuine Teryair or Teryair approved atmospheres—Part 36 :Non-electrical accessories. equipment for explosive atmospheres— Basic metod and requirements...
  • Page 5: Installation Instructions

    Operation and Maintenance Guide 16 VM Air Motor Series Page 5 Safety wear mandatory while operating Vane should not exceed 80º C. Do not continue motor to operate the motor if the measured surface temperature exceeds temperature listed on the Air stream from product may contain solid o motor.
  • Page 6: Operating Instructions

    Lube-free. Hoses • Daily before operation check the hoses, especially the high pressure hoses for damage or leaks • Use genuine Teryair spares and if possible mention the serial number of the Vane motor when ordering spares. FF-MM-372-REV - 02...
  • Page 7: Suggested Lubricants

    Operation and Maintenance Guide 16 VM Air Motor Series Page 7 Suggested Lubricants Brand Above 27 Deg C ( From 5 Deg C to 27 Deg C Below 5 Deg C Shell Toona R 72 Toona R 41 Toona R 27 Mobil Almo 529 Almo 527...
  • Page 8: Dis Assembly And Re-Assembly

    Operation and Maintenance Guide 16 VM Air Motor Series Page 8 Dis assembly and Re-assembly new ones (if worn-out). Disconnect air supply and vent all air lines. Air stream from product may contain solid or h. Now insert Pins (7) into the Rotor Shaft’s liquid material that can result in eye or skin (6) through holes (use small amount damage.
  • Page 9: Exploded View For 16Vm Air Motor

    Operation and Maintenance Guide 16 VM Air Motor Series Page 9 Exploded View for 16VM Air Motor FACE NEMA FF-MM-372-REV - 02...
  • Page 10: Bill Of Materials For 16Vm Series (Sg Iron)

    Operation and Maintenance Guide 16 VM Air Motor Series Page 10 Bill of Materials for 16VM Series (SG Iron) Illu. Part Description FACE/ FOOT NEMA Number 16VMLAL 16VMLOL 16VMDAL 16VMDOL 16VMNAL 16VMNOL HOUSING-NPT 810 05 01 HOUSING -NPT (LUBE-FREE) 810 05 01LF HOUSING-BSPT 810 05 08 HOUSING -BSPT (LUBE-FREE)
  • Page 11: Bill Of Materials For 16Vm Series (Ss316)

    Operation and Maintenance Guide 16 VM Air Motor Series Page 11 Bill of Materials for 16VM Series (SS) Illu. Part Description FACE/ FOOT NEMA Number 16VMLAS 16VMLOS 16VMDAL 16VMDOL 16VMNAS 16VMNOS HOUSING-NPT 810 07 01 HOUSING -NPT (LUBE-FREE) 810 07 01LF HOUSING-BSPT 810 07 08 HOUSING -BSPT (LUBE-FREE)
  • Page 12: Dimensional Data

    Operation and Maintenance Guide 16 VM Air Motor Series Page 12 Dimensional Data FACE and Foot Mounting 16VM NEMA Mounting 16VM FF-MM-372-REV - 02...
  • Page 13: Repair Kits For 16Vm

    Operation and Maintenance Guide 16 VM Air Motor Series Page 13 IEC Mounting 16VM Repair Kits for 16VM Repair KIT Ordering No Suitable for 8109701 Suitable for 16 VM all variant Note - Repair Kit includes Blades, Bearings, Shims, Blade springs, Oil Seals and O rings FF-MM-372-REV - 02...
  • Page 14: Test Certificate Of Materials, Performance

    Operation and Maintenance Guide 16 VM Air Motor Series Page 14 TEST CERTIFICATE OF MATERIALS, PERFORMANCE DATE MODEL NUMBER PART DESCRIPTION & S.NO. We Hereby Certify That The Above Referenced Product Has Tested And Inspected In Accordance With Our Standard Test Pro- cedures And Meets The Specifications For Material And Performance Values As Published In Our Literature.
  • Page 15: Eu Declaration Of Conformity

    Notified body to whom Technical file has logged with: - Technicka Inspekcia (Ref: 1354). DECLARATION: - TERYAIR EQUIPMENT PVT. LTD., declare that under our sole responsibility for the supply of the product defined above, the said product complies with all the applicable Directives, Regulations and all essential Health and Safety requirements applying to it.
  • Page 16: Warranty Certificate

    Teryair; (vii) the issue with a Product is directly or indirectly attributable to, or directly or indirectly results from or arises out of, compliance with any design, specification or other specific requirement of Dealer/End User;...
  • Page 17 Operation and Maintenance Guide 16 VM Air Motor Series Page 17 This page is intentionally Left blank. FF-MM-372-REV - 02...

This manual is also suitable for:

16vml series16vmn series16vmd series

Table of Contents