TECHNICAL CHARACTERISTIC TABLES
BURNERS
DESCRIPTIONS
1
RAPID
2
SEMI-RAPID
3
AUXILIARY
TRIPLE RING
4
SABAF
DOUBLE RING
5
DEFENDI
Short title or reference to the measurement and calculation methods used to establish compli-
ance with the above requirements.
The performance of each individual burner is calculated according to standard EN 30-2-1 + A1:2003 +
A2:2005
The total efficiency of the hob is calculated according to the EU Regulation 66/2014 Par. 2.2
The efficiency is calculated only for the burners with a nominal capacity exceeding 1,16 KW ( EN 30-2-1
+ A1:2003 + A2:2005; Par. 4.1)
Information which is relevant to the customer to minimize the energy consumption during usage:
Energy Saving Tips: use pots having flat base, Use pots with proper size, use pots with lid, minimize the
amount of liquid or fat, when liquid starts boiling reduce the setting.
This product complies with EU Directive 2002/96/EC.
The crossed-out dustbin symbol reported on the appliance indicates that the appliance must be
disposed of separately from other domestic refuse at the end of its useful life. It must therefore be
delivered to a waste recycling centre specifically for electric and electronic equipment or returned
to the retailer at the moment of purchase of a new equivalent appliance.
The user is responsible for delivering the appliance to the appropriate collection centre at the end of its useful
life, Failure to do so may result in a fine, as provided for by laws governing waste disposal. Differential collection
of waste products for eventual recycling, treatment and environmentally friendly disposal helps reduce possible
negative effects on the environment and health, and also enables the materials making up the product to be
recycled. For more detailed information on the available refuse collection systems, refer to the local Municipal
Solid Waste disposal centre or the shop where the product was purchased. Producers and importers are
responsible for fulfilling their obligations as regards recycling, treatment and environmentally friendly disposal by
directly or indirectly participating in the collection system.
NORMAL
PRESSURE
GAS
mbar
G30 - G31
28 - 30
G20
20
G30 - G31
28 - 30
G20
20
G30 - G31
28 - 30
G20
20
G30 - G31
28 - 30
G20
20
G30 - G31
28 - 30
G20
20
NORMAL
I N J E C T O R
RATE
DIAMETER
g/h
L/h
1/100 mm
225
-
85
-
290
115Y
126
-
65
-
165
97Z
71
-
50
-
99
72X
278
-
98
-
367
135K
255
-
93
-
334
135
11
TAPE BY
NOMINAL HEAT
PASS
INPUT (W)
DIAMETER
1/100 mm
Max.
Min.
42
3000
950
Reg.
3000
950
31
1750
600
Reg.
1750
600
27
1000
450
Reg.
1000
450
60
3800
2100
Reg.
3800
2100
60
3500
2100
Reg.
3500
2100
(EE
gas
)
hob
(%) *
56.7
57
/
58.1
56.6