Download Print this page

Component Tests - Maytag MED5920TW0 Manual

Advertisement

PAGE 4
Component Location
Console Shell
Push to Start
Screws,
(PTS)
R.H. Side (2)
Switch
A.C. Heater
A.C. Heater
Relay
Relay Screws
(2)

COMPONENT TESTS

Supply Connections Test
This test assumes that proper voltage is
present at the outlet, and visual inspection
indicates that the power cord is securely
fastened to the terminal block.
1. Unplug dryer or disconnect power.
2. Remove the cover plate from the back of
the dryer.
3. With an ohmmeter, check for continuity
between the neutral (N) terminal of the
plug and the center contact on the
terminal block. See illustration below.
Power Cord
Plug
L1
N
COM
Plug-to-terminal connections for electric
dryer.
If there is no continuity, replace the
power cord and test the dryer.
If there is continuity, go to step 4.
4. In a similar way, check which terminal of
the plug is connected to the left-most
contact on the terminal block and make
a note of it. This will be L1 (black wire) in
the wiring diagram. See illustration
above.
PART NO. W10114943A
Temperature
Ground
Timer Screws
Switch
Screw
D.C. Heater
D.C. Heater
Relay
Relay Screws
(2)
When this is found, go to step 5.
If neither of the plug terminals have
continuity with the left-most contact of
the terminal block, replace the power
cord and test the dryer.
5. Access the electronic control without
disconnecting any wiring to it.
6. With an ohmmeter, check for continuity
between the L1 terminal of the plug
(found in step 4) and BK (black wire)
terminal on the timer.
If there is continuity, go to step 7.
If there is no continuity, check that
wires to the terminal block are
mechanically secure. If so, replace or
repair the main wire harness and test
the dryer.
Terminal Block
7. Check for continuity between the neutral
(N) terminal of the plug and P2-1 (white
wire) on the electronic control.
If there is continuity, go to the Timer
Test.
If there is no continuity and the
mechanical connections of the wire
are secure, replace or repair the main
wire harness.
Timer Test
Perform the diagnostic test on page 1 to
determine that the timer motor advances
(should run continuously). If the timer does
not advance or fails the diagnostic test:
1. Unplug dryer or disconnect power.
2. Remove the wires from timer terminals.
Control
(2)
Bracket
Timer
Electronic
Control
TECH SHEET - DO NOT DISCARD
Wrinkle Prevent
Signal
Switch
Switch
D.C.
D.C. Motor
Motor
Relay Screws
Asm
Relay
3. Check the timer motor resistance and
timer switching. The resistance (BU to
PT-1) should be 3 kΩ (±2). Use the timer
encoding table below for switching
conductivity, and refer to timer illustration
on page 2.
Reference contact continuity to timer - BK.
Timer Encoding Table
TIMED DRYING MODE
Timer
Timed
Contacts
Drying
W to BK
O
R to BK
X
V to BK
O
BU to BK
X
SENSOR DRYING MODE
Timer
Energy
Jeans
Contacts
Preferred
W to BK
X
X
R to BK
O
O
V to BK
X
O
BU to BK
X
X
O = OPEN
Motor Test
1. Unplug dryer or disconnect power.
2. Open the dryer door.
3. Measure resistance between the motor
relay common (COM) terminal and the
P2-6 terminal on the electronic control.
1 to 6 Ω should be measured.
If resistance measurements are
outside 1 to 6 Ω, perform the Thermal
Fuse Test and Door Switch Test,
page 5; and check harness continuity.
If they test good, replace the motor.
FOR SERVICE TECHNICIAN'S USE ONLY
Console
Console Shell
Shell
Screws,
L.H. Side (2)
(2)
Cool
Wrinkle
Off
Down
Prevent
O
O
O
X
O
O
X
X
O
X
X
O
Less
Wrinkle
Off
Dry
Prevent
O
O
O
O
O
O
O
X
O
X
X
O
X = CLOSED

Advertisement

loading