Chap 7 Settings - Maidaid Halcyon C612 User's Installation Manual

Table of Contents

Advertisement

The following settings should only be configured by a qualified technician.
The parameters listed below can be set during installation of afterwards, accessing the settings menu as
follows:
Machine in standby with door open.
Press buttons 1 and 2 together (ON/OFF and SPECIAL PROGRAMME SELECTION) for 5 seconds
and enter the key CH 12 (buttons 3 and 4 to change the parameter, 1 to confirm).
Then press button 1 (ON/OFF) repeatedly to scroll through the following headings, enabling and/or
changing them using buttons 3 and 4 (the modified parameter is memorised without being
confirmed). The list of parameters may vary according to the type of dishwasher.
Language
Boiler
Temperature
Tank
Temperature
Thermo - Stop
Energy
Saving
Detergent
Pump
Rinse Aid
Pump
Manual
Rinse
Dosage
Detergent
Dosage
Rinse Aid
Water
Hardness
Set Number
Service Cycles
Autostart
Autoenabling
Manual Drain
Once all necessary parameters have been set, to exit and memorise any changes simply press and
hold button 1 for a few seconds until the on-line dashes appear.
INSTRUCTION MANUAL FOR DISHWASHERS
Language selection
Boiler temperature settings for programmes. In the versions with
atmospheric boiler (rinse pump) there are different settings for each
programme (b1 – b2 – b3)
Tub temperature regulation for programmes. Rinse pump versions have
different settings for each programme (t1 – t2 – t3)
Enabling the Thermostop function, which guarantees the correct
rinse temperature.
Enabling the Energy Saving function, which guarantees
energy savings when the dishwasher is on but not in use.
Manual operation of detergent doser
Manual operation of rinse aid doser
Manual operation of the rinse pump
Detergent dosing time
Rinse aid dosing time
Setting the supply water hardness (dishwashers with water softener): enter
the values given in the table below
Cycle counter setting and activation to enable the Service alert for an
external water softener.
The Service alert can be cancelled by holding pressed all 4 buttons with
the machine off and the door open.
Automatic enabling of automatic starting
Manual operation of the drain pump