Danby DDR050BCWDB-ME-6 - 50 Pint Dehumidifier Manual

Danby DDR050BCWDB-ME-6 - 50 Pint Dehumidifier Manual

Also See for DDR050BCWDB-ME-6:

Advertisement

Danby DDR050BCWDB-ME-6 - 50 Pint Dehumidifier Manual

Important Safety Information


READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SAFETY REQUIREMENTS

This appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities may be different or reduced, or who lack experience or knowledge, unless such persons receive supervision or training to operate the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
To avoid risk of electric shock, do not operate this dehumidifier in an area that is likely to accumulate standing water. If this condition develops, disconnect the power supply before stepping into the water.
Do not store or use combustible materials such as gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
Do not insert fingers or other objects into grills or openings in the appliance.
Do not cover or block the intake and exhaust openings.
Do not operate the appliance without the filter installed.
Do not operate the appliance near heat sources.
This appliance is intended for indoor, residential applications only. Do not use this dehumidifier outdoors. Do not use this dehumidifier for commercial or industrial applications.

GROUNDING INSTRUCTIONS

This appliance must be grounded. Grounding reduces the risk of electrical shock by providing an escape wire for the electrical current.
This appliance has a cord that has a grounding wire with a 3-prong plug. The power cord must be plugged into an outlet that is properly grounded.
If the outlet is a 2-prong wall outlet, it must be replaced with a properly grounded 3-prong wall outlet. The serial rating plate indicates the voltage and frequency the appliance is designed for.

Improper use of the grounding plug can result in a risk of electric shock.
Consult a qualified electrician or service agent if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.
Do not connect the appliance to extension cords, adapters or together with another appliance in the same wall outlet.
Do not splice the power cord. Do not under any circumstances cut or remove the third ground prong from the power cord.
If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified person in order to avoid hazard.

INSTALLATION INSTRUCTIONS

ASSEMBLY

  1. Remove all packaging.
  2. Lift the dehumidifier by the handle, pull out the power cable and rotate the dehumidifier 90 degrees clockwise.
  3. Place the dehumidifier onto the water bucket according to the "ALIGN" labels and press down gently until it clicks into place.
    Assembly

CASTER INSTALLATION

  1. Slide the four casters into the slots on the bottom of the dehumidifier.
  2. Press down on the caster lock to secure the caster.
    Caster Installation - Step 1
  3. To remove the casters, lift up the caster lock with a screwdriver and then slide the caster out.
    Caster Installation - Step 2

OPERATING INSTRUCTIONS

FEATURES

Features Overview

  1. Air outlet
  2. Control panel
  3. Handle
  4. Water bucket
  5. Casters
  6. Air intake
  7. Air filter (behind the grill)

DEFAULT SETTING

The default setting is continuous mode and high fan speed. This means that when the dehumidifier is plugged in for the first time it will run in continuous mode with the fan speed set to high.
Press the mode button to change the mode, if desired. Press the humidity adjust buttons to set the desired humidity. Ensure that the set humidity is lower than the ambient humidity.

OPERATION

  • Place the dehumidifier on a smooth, level floor that is strong enough to support the appliance with a full bucket of water.
  • Do not place the dehumidifier on carpeting as this can block air fl ow around the appliance. Do not force casters to move over carpeting as the appliance can become unbalanced and spill water.
  • To maintain efficiency, operate the appliance in an enclosed area. Keep nearby doors and windows closed.
  • Maintain a minimum clearance of 40 cm (16 inches) around the air outlets and 20 cm (8 inches) on other sides of the appliance to allow for proper air circulation.
  • The recommended ambient operating temperature is between 5°C (41°F) and 32°C (90°F). Low ambient operating temperatures can cause frost to form on the internal coils which may affect performance.
  • Any time the appliance is placed on its back or side, it must be allowed to stand upright for 6 hours before plugging in to avoid damage to internal components.
  • For optimal performance, ensure that the humidity setting is 10% lower than the ambient humidity. It is normal for the ambient humidity to vary up to 5% above or below the set humidity.
  • It is recommended in normal conditions to set the humidity between 40-45%.
  • It is normal for the dehumidifier to exhaust warm air.

CONTROL PANEL

Control Panel Overview

  1. Power button:
    • Press to turn the dehumidifier on or off.
    • Press and hold for 3 seconds to activate the wireless connection.
  2. Humidity adjust buttons: The humidity level can be set within a range of 35% to 85% relative humidity in 5% increments. For drier air, set to a lower percentage value. For more damp air, set a higher percentage value.
  3. Fan button:
    • Press to select normal or high fan speed.
    • After 250 hours of operation, the filter light indicator will illuminate on the display. Clean the filter and then press and hold the fan button for 3 seconds to reset the filter indicator.
  4. Mode button: Press the mode button to select the desired mode.
    • Set mode: the humidity level and fan speed can be set manually by the user.
    • Continuous mode: the dehumidifier will run continuously. The humidity level cannot be adjusted. The fan speed can be adjusted.
    • Max mode: the dehumidifier will run continuously. The humidity level cannot be adjusted. The fan speed will be set to high and cannot be adjusted.
  5. Fill level button:
    • Press the fill level button to choose the bucket capacity: 1, 2, 3 or 4.
  6. Timer button: Press to set the timer.
  7. Display:
    • Shows the set humidity level between 35% to 85% relative humidity while setting, then shows the ambient humidity in a range of 30% to 90% relative humidity with an accuracy of ±5%.
    • Displays the timer settings.
    • Shows all error codes.
      1. Indicator will illuminate when the wireless connection is active.
      2. Indicator will illuminate when the filter needs to be cleaned.
      3. Indicator will illuminate when the dehumidifier is being used without the bucket installed.

TIMER

The timer can be used to set the dehumidifier to turn off or on after a set period of time.

Auto Off

  1. When the dehumidifier is turned on, press the timer button to activate the auto off timer.
  2. Press the humidity adjust buttons to change the set time in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours.

Auto On

  1. When the dehumidifier is turned off, press the timer button to activate the auto on timer.
  2. Press the humidity adjust buttons to change the set time in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours.

The auto on and auto off timers can be used at the same time by first setting one and then the other.
The timer will not cycle the dehumidifier on and off indefinitely. The auto on and auto off timers will function one time and then the dehumidifier will return to regular functioning.
Turning the dehumidifier on or off at any time or changing the timer setting to 0.0 will cancel the timer settings. The P2 bucket full bucket error code will also cancel the timer setting.

WIRELESS CONNECTION

This appliance can be controlled with a wireless application on your wireless device.
Visit https://www.danby.com/support/apps to download the application and learn about its operation.

WATER REMOVAL

  1. Water Bucket
    The dehumidifier will automatically collect condensed water in the water bucket. When the bucket is full, the compressor and fan will turn off and the full bucket indicator light will turn on. The display will show "P2".
    To empty the bucket, lift the dehumidifier handle and separate the body from the water tank. Put the dehumidifier body on a flat, solid surface. Empty the bucket but be cautious when moving the bucket, it will be full and can be heay. The dehumidifier will resume functioning when the body is reconnected to the water bucket.
  2. Continuous Drain
    Water can be removed using the continuous drain with either the provided drain hose or a standard garden hose.
    The provided clear plastic drain hose is 2 feet (0.6 m) long. If there is no available drain within range of the dehumidifier, a garden hose can be attached instead. Please note, the garden hose should be no longer than 6 feet (1.8 m). If the drain hose is too long water may not drain completely which can lead to stagnant water and mildew build up inside the hose.
    To attach to continuous drain hose:
    1. Remove the cover located on the back of the
    2. Remove the plug from the continuous drain outlet and attach the desired hose.
    3. Direct the other end of the hose to a bucket or floor drain.

      Ensure that the hose is not bent and goes straight down from the back of the appliance. The continuous drain is only activated by gravity so any bends or upward motion in the hose will stop the water from draining.

BUCKETLESS MODE

The dehumidifier can be used without the bucket installed. This means the dehumidifier will continue to remove water from the air and will not check if the bucket is installed.
Do not use bucketless mode without a drain hose attached. Ensure that the hose is securely connected before turning on the dehumidifier. Direct the other end of the drain hose to a place with unlimited capacity such as a sink or floor drain. Directing the drain hose to a place with limited capacity could cause the water to overflow.
To turn on bucketless mode:

  1. Connect the drain hose to the dehumidifier.
  2. Connect the dehumidifier to a power source. Do not install the water bucket.
  3. "Eb" will show on the display.
  4. Press and hold the fill level button and the up button at the same time for 3 seconds to set the dehumidifier to run without the bucket.
  5. The bucketless indicator will illuminate on the display.

To turn off bucketless mode:

  1. Press and hold the fill level button and the up button at the same time for three seconds.
  2. Turn off the dehumidifier. Ensure the bucket is installed before turning it back on again.


there is a micro switch on the bottom of the dehumidifier that engages with the bucket. Bucketless mode may be automatically turned off if this switch is pressed. Ensure that the space is clear and that you do not touch the micro switch.

BUCKETLESS DRAIN

Ensure that the dehumidifier is placed on a flat, level surface to prevent toppling or sliding. The tilt angle needs to be less than 1 degree.

Ensure that the drain hose is properly connected before turning on bucketless mode.

There is no drain pump in this dehumidifier, the drain operates through gravity. The drain hose must angle down from the back of the dehumidifier at least 10 cm or more. The hose cannot lie flat or be angled upward.

CARE & MAINTENANCE

CLEANING

To avoid possible electric shock, ensure that the appliance is unplugged before performing any cleaning or maintenance.
The outside of the appliance can be wiped clean with a soft cloth or with a lukewarm, damp cloth if necessary.
Do not use gasoline, benzene, thinner or any other chemicals to clean this appliance as these substances can cause damage to the finish and deformation of plastic parts.
Never pour water directly onto the appliance as this will cause deterioration of electrical components and wiring insulation.
Ensure that the drain ports on the back of the appliance are free of dirt and calcium build up.

AIR FILTER

The air filter should be cleaned approximately every 2 weeks. The air filter may require more frequent cleaning if there is significant dander or fur in the air.
Every 250 hours or approximately every ten days, the filter indicator light on the control panel will illuminate as a reminder to clean the filter. Follow the steps below to clean the filter and return the appliance to normal functioning.

  1. The air filters are located behind the two side grills. Grip the side handles and pull gently forward to remove them.
  1. Use a vacuum cleaner with a soft brush attachment to remove any large debris or dust build up from the air filter.
  1. Wash the filter in lukewarm, soapy water, below 40°C (104°F), or use a neutral cleaning agent.
  1. Rinse the filter with clean water and dry thoroughly before reinstalling in the appliance.
  1. Press and hold the fan button for 3 seconds to reset the filter indicator.

Note: Do not operate the appliance without the air filter installed. Do not place the filters in a dishwasher.

ERROR CODES

If the display panel shows any of the below error codes, unplug the dehumidifier, let it stand for 5-10 minutes and then plug it back in. If the error persists, call for service.

EH60 - room temperature sensor error
EH61 - evaporator sensor error
EH0b - display board or master control board communication error
P2 - bucket is full
Eb - bucket is not installed

POWER FAILURE

In the event of a power failure or if the appliance is unplugged, it will resume normal functioning when power is restored. The mode and fan speed will resume at the settings chosen before the power failure.

AUTO DEFROST

When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost melts. The dehumidifier may emit the sound of running water. This is the refrigerant moving through the coils and is normal.

END OF SEASON CARE

Unplug the dehumidifier and ensure the filter is clean. Ensure the bucket is empty and then allow both the bucket and the dehumidifier to dry completely before storing for the off season.
It could take a few days for water inside the dehumidifier to completely evaporate. Wipe the bucket with a dry cloth and ensure the drain has been emptied to speed up this process Store the dehumidifier covered in a dry location.

DISPOSAL

This appliance may not be treated as regular household waste, it should be taken to the appropriate waste collection point for recycling of electrical components. Check for local regulatory compliance regarding approved and safe disposal of this appliance.

FREQUENTLY ASKED QUESTIONS

What is the best humidity setting?
The recommend humidity setting is 40-45%.

Is the air that comes out of the dehumidifier supposed to be hot?
Yes, usually this air feels warm.

Why isn't the dehumidifier collecting any water?
There may not be enough humidity in your environment or the relative humidity might be set higher than ambient humidity.

Does the fan run continuously?
In continuous mode and max mode the fan will run continuously. In a manual setting the fan will cycle on and off.

Can I use an extension cord?
No, the dehumidifier is built to operate using the power cord provided.

Does the timer cycle on and off forever?
The on and off timers can be used at the same time however, they will only cycle one time and then resume normal functioning.

How do I hook up my direct drain?
Use the provided drain hose or purchase a garden hose. See page 7 for more information.

Does the filter light turn on when it is dirty?
The filter light turns on automatically after about 250 hours of use even if the filter is clean. Clean the filter and then hold the fan button for 3 seconds to turn the filter light off.

TROUBLESHOOTING

Appliance will not operate

  • Plug is not fully inserted into the wall outlet
  • Blown fuse or circuit breaker
  • Ambient humidity is lower than the set humidity
  • Bucket is full or is not in the proper position

Insufficient dehumidifying

  • Air filter is dirty
  • Blocked air flow
  • Appliance size is too small for application
  • Ambient humidity is lower than the set humidity

Noise

  • Air filter is dirty
  • Bucket is not in proper position
  • Floor surface is not level

Odors

  • Formation of mold or mildew on internal wet surfaces
  • Place an algaecide tablet in the water bucket

Water on floor

  • Hose connection is loose
  • Drain cover has been removed

Frost build up

  • When ambient temperature is below 5°C (41°F) frost may form
  • Switch the appliance to fan only mode until the frost melts

www.Danby.com

Danby Products Limited, Guelph, Ontario, Canada N1H 6Z9
Danby Products Inc. Findlay, Ohio, U.S.A. 45840

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Danby DDR050BCWDB-ME-6 - 50 Pint Dehumidifier Manual

Advertisement

Need Assistance?

Do you have a question about the DDR050BCWDB-ME-6 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents