Light-curing unit for dental laboratories
USER MANUAL
Introduction
Thank you for purchasing our Solidilite LED. The instructions mentioned
below provides the necessary information for successful operation, daily
maintenance and safe use of this unit. Please read this user manual
carefully before use to attain maximum benefits and ensure the durability
of this unit.
Kindly keep this manual for your future reference.
Notice
● No part of this document may be copied or reproduced in any form by any
means.
● Some information in this document may no longer be applicable to the
product due to product updates.
● The information in this document is subject to change without prior notice.
● All relevant issues have been considered in the preparation of this
document. However, should you notice an omission or any questionable
item in this document, please feel free to contact your dealer.
● In the case of missing pages or disorder, please contact our local dealer
for replacement.
● SHOFU will repair and replace the main body and its system in the case of
any manufacturing defect within the warranty period. However, we do not
assume any responsibility for subsequent damages arising from the failure
of the unit.
Intended use
Light-curing of dental indirect composite resins
Post-curing of light-cured dental materials
1. For your safety
Understand the following items to use the product safely.
Warnings and Cautions
This manual provides safety information using the following 2 symbols to
prevent accidents resulting in injury or death.
Understand the meaning of these symbols to operate the unit safely.
"Warning" indicates a potential hazardous situation which,
CAUTION
Warning
if not avoided, could result in death or serious injuries.
"Caution" indicates a potentially hazardous situation which,
CAUTION
if not avoided, may result in minor or moderate injury or in
Caution
property damage.
IEC 62471 risk group 2
CAUTION
Caution
● UV emitted from this product. Eye or skin irritation may result from
exposure. Use appropriate shielding.
● Possibly hazardous optical radiation emitted from this product.
Do not stare at operating lamp. May be harmful to the eye.
Product tested against IEC 62471
Other notes and signs
Other notes and signs used in this manual are shown below.
Indicates that malfunctions may occur if the information is
Note
ignored.
Supplementary explanation to facilitate your operation.
Info
Installation and connection
CAUTION
Warning
● Use only suitable power sockets with ground contacts.
Electric leakage inside the unit may lead to electric shock or fire.
● Keep away from any source of ignition or flammable items to avoid
explosion or fire.
● Keep away from water or any other liquid to avoid electric shock,
electric leak or fire.
CAUTION
Caution
● Ensure that the power plug is free of dust and connected securely to
the outlet. Use this unit in a dry and well ventilated area.
Failure to do so may lead to fire.
● Use one outlet supplying the necessary power exclusively for this
unit to avoid overloading the circuit.
If the power supply is insufficient, the outlet will overheat, which might
result in fire or electric shock.
● Place the unit on a flat and sturdy table that withstands its weight.
Failure to do so may cause injuries if the unit falls down.
● Leave a gap of at least 20 cm (8 inches) from all sides and 30 cm
(12 inches) from the top of the unit.
If adequate space is not provided for release of heat, the unit will overheat
leading to smoke or fire.
Operation
CAUTION
Warning
● Do not insert and pull out the plug from the outlet with wet hands.
This may cause electric shock.
● Protect the unit from liquids or high humidity to avoid electric leak,
electric shock or fire.
● If there is any smoke or burning smell, immediately turn off the
power, unplug the power cable and request for repair.
Failure to do so may cause electric shock or fire.
CAUTION
Caution
● Unplug by holding the plug instead of the power cord.
Failure to do so may lead to injury, burn, electric shock or fire due to
deterioration of the insulation.
● Never damage / reprocess or apply unnecessary force on the power cord.
A damaged power cord may cause electric shock or fire.
● Do not open the chamber door during light irradiation.
This may be harmful to the eyes due to direct exposure to the curing light.
● Do not touch the door switch or insert any object.
This may cause malfunction of the unit and also be harmful to the eyes
due to direct exposure to the curing light.
● Turn off the power after use. Also, unplug when not using this unit
for a long period of time.
Deterioration of the insulation may lead to electric shock or fire.
● Do not use this unit for any purposes other than specifically outlined
in this user manual.
Improper use may cause injuries.
● If there is any abnormality during use, immediately discontinue use
and inspect the unit following the instructions for use or contact your
dealer for repair.
Failure to do so may cause electric shock or fire.
● If the unit is accidentally dropped, inspect it following the instructions
for use or contact your dealer for repair.
Failure to do so may cause electric shock or fire.