To view the thermistor temperature, push and release the
USER GUIDE
DISPLAY/OPTIONS
up and down keys. The display will show the corrected
Unit will immediately turn ON or OFF
refrigerator temperature.
only.

SHOWROOM MODE

When the "F" or "C" in the display is flashing,
This mode is designed to show units in a display environ-
push
or
to adjust the set point
ment. When in this mode the only functions will be the
temperature.
control and cabinet lights. The compressor, fans, etc. will
The display will flash and then toggle from set
not operate. To enter/exit this mode hold the light key
point to temperature in unit.
and the power key for 5 seconds. The display will flash
The display will change units.
once and beep and the degree symbol will begin to flash.
When the degree symbol is flashing the unit will allow the
use of the control for demonstrations. The unit can be left
in this mode indefinitely.

ACCESS SERVICE MODE

SERVICE MODE
This mode has options available for service diagnostics.
To access the service menu for this model, remove the
To enter the mode hold the hidden key for 10 seconds.
two screws that hold the display together.
The display will show "0." When in this mode use the up
Remove display circuit board. Press and hold the far left
and down arrows to select the desired option. The LIGHT
button on the display circuit board.
key is the ENTER key and will initiate the function. If
changing a setting, you must press the LIGHT key again
to retain the changed setting. To exit the service mode
Press and Hold
scroll to option "0" and press the LIGHT key. After five
minutes of not touching any keys the mode will also exit
automatically.
Control Operation-Service
Control Operation - Service 2
USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING
SERVICE MODE GUIDE
#
Service Mode Menu Item
1
View thermistor #1 (no offsets)
2
View thermistor #2 (no offsets)
3
View thermistor #3 (no offsets)
4
View thermistor #4 (no offsets)
5
Adjust thermistor #1 offset
6
Adjust thermistor #2 offset
7
Adjust thermistor #3 offset
8
Adjust thermistor #4 offset
9
View thermistor #2 set point no offsets
10
View thermistor #3 set point no offsets
11
View thermistor #4 set point no offsets
12
Adjust defrost interval 3 to 24 hours
13
Adjust defrost duration 0 to 99 minutes
14
View error log
15
Clear error log
16
Adjust thermistor #1 differential
17
Adjust evaporator fan delay in minutes (start of cooling
cycle)
0 - 99 minutes
18
Adjust evaporator fan delay in minutes (after cooling
cycle stops)
0 - 99 minutes
19
Individual component toggle
20
Model number indicator
21
Light all LED segments of display
22
View defrost cycles
23
View compressor run time
24
Activate defrost/harvest
25
Restore factory defaults
26
View software version - main board
27
View software version - user interface
28
Login period
29
Factory test mode
0
Exit service mode
NAVIGATE SERVICE MODE
Use up or down arrows to scroll through the menu.
Use the light bulb key to enter or exit menu. If values
have been changed, they will be saved when exiting.
55
Control Operation - Service 2
S
1
2
3
4
5
6
7
8
9
1
1
1
1

Advertisement

Table of Contents
loading

Table of Contents