Download Print this page

U-Line UHRE524-SS81A User Manual & Service Manual

Hide thumbs Also See for UHRE524-SS81A:

Advertisement

Quick Links

USER GUIDE & SERVICE MANUAL
Model: UHRE524-SS81A

Advertisement

loading

Summary of Contents for U-Line UHRE524-SS81A

  • Page 1 USER GUIDE & SERVICE MANUAL Model: UHRE524-SS81A...
  • Page 2 USER GUIDE & SERVICE MANUAL Click on any section below to jump directly there Table of Contents Intro Wire Diagram Product Liability Safety Warranty Claims Safety and Warning Parts Disposal And Recycling Ordering Replacement Parts R600a Specifications Installation System Diagnosis Guide Environmental Requirements Compressor Specifications Electrical...
  • Page 3 U-Line Customer Care must be contacted immediately at +1.414.354.0300. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 4 USER GUIDE Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5 USER GUIDE Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely:...
  • Page 6 USER GUIDE Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.
  • Page 7 USER GUIDE Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8 Cutout & Product Dimensions 23 ⁄ ” (600 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit FRONT does not require additional air space for top, sides, or 33 ⁄ ”...
  • Page 9 USER GUIDE Side-by-Side Installation Hinge-by-Hinge Installation (Mullion) When installing two units hinge-by-hinge, 13/16" (22 mm) OTHER SITE REQUIREMENTS is required for integrated models. Additional space may be Side-by-Side Installation needed for any knobs, pulls or handles installed. Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s electrical specifications requirements.
  • Page 10 USER GUIDE Anti-Tip Bracket Surrounding area (Top view) Use one of the methods below to secure the unit CABINET/COUNTER ANTI-TIP INSTALLATION (For built-in applications) Back of unit Back wall Slide unit out so screws on front of unit are easily accessible.
  • Page 11 USER GUIDE General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable. level.
  • Page 12 USER GUIDE Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. WARNING DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged. Removing the grille 1.
  • Page 13 USER GUIDE Door Swing Wall For Integrated models that are installed adjacent to a wall, 1/2" (13 mm) 1/2" (13 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space for any knobs or pulls installed on the integrated panel/frame.
  • Page 14 USER GUIDE Door Stop Your U-Line unit was shipped to you with the optional 90° pin. Your unit’s door(s) will open 115° straight from the factory. If you would like the door stop at 90°, follow these instructions. NOTICE If your unit is already undercounter, it will need to be moved out to access the hinge.
  • Page 15 USER GUIDE Door Adjustments REVERSING THE DOOR Open door. DOOR ALIGNMENT AND ADJUSTMENT Using T-25 Torx bit loosen screw #1 and remove screw Align and adjust the door if it is not level or not sealing #2 on top and bottom hinge. Slide and remove the properly.
  • Page 16 If the temperature displayed is different than selected, the unit is progressing towards the selected temperature. Time to reach set point varies based upon ambient temperature, temperature of product loaded, door openings, etc. U-Line recommends allowing the unit to reach set points before loading.
  • Page 17 USER GUIDE Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and release Unit will immediately turn On or OFF When the display is flashing, press Adjust Temperature Press and release adjust the set point temperature. Note: temperature displayed is the actual temperature inside unit Option Open Door Closed Door...
  • Page 18 See Control Operations sections for details and other options. For more information about BrightShield™ visit www.u-line.com For more information about Vyv™ Antimicrobial Light Technology visit www.vyv.tech...
  • Page 19 ⁄ ” ⁄ ” (66 mm) (64mm) When determining capacities U-Line uses typical 12 oz. cans, 12 oz. bottles, 750 mL white wine and red wine bottles shown below. ⁄ ” ⁄ ”...
  • Page 20 USER GUIDE Interior Adjustments Once removed, retract the slides. Note: The slides on the frame have a thin coating All 5 Class models feature side mounted rack supports with which is used to block moisture and provide 19 adjustment positions. lubrication.
  • Page 21 USER GUIDE Cleaning To clean integrated panels, use household cleaner per the cabinet manufacturer’s recommendation. Stainless Models Stainless door panels and handles can discolor when INTERIOR CLEANING exposed to chlorine gas, pool chemicals, saltwater or Disconnect power to the unit. cleaners with bleach.
  • Page 22 USER GUIDE NOTICE The drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring, the unit must be removed from cabinetry. To defrost: 1.
  • Page 23 USER GUIDE Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary. WARNING Disconnect electric power to the unit before cleaning the condenser.
  • Page 24 If the unit will be exposed to temperatures of 40°F (5°C) or less, the steps above must be followed. For questions regarding winterization, please call U-Line at 414.354.0300. CAUTION Damage caused by freezing temperatures is not covered by the warranty.
  • Page 25 BEFORE CALLING FOR SERVICE • Condenser Fan: Air moving through a condenser may be heard. If you think your U-Line product is malfunctioning, read the CONTROL OPERATION section to clearly understand the • Automatic Defrost Drain Pan: Water may be heard function of the control.
  • Page 26 USER GUIDE CHECKING PRODUCT TEMPERATURE Causes which affect the internal temperatures of the cabinet include: • Temperature setting. • Ambient temperature where installed. • Installation in direct sunlight or near a heat source. • The number of door openings and the time the door is open.
  • Page 27 USER GUIDE u-line.com Wire Diagram Wire Diagram...
  • Page 28 The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 29 Claims must be submitted online at • Final billing - Remodel www.U‑LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
  • Page 30 USER GUIDE Parts UHRE524-SS01A ANTI-TIP BRACKET 80-55449-00 BACK PANEL 80-55481-00 STORAGE BIN 80-54059-00 BIN FRONT 80-55482-00 COMPRESSOR W/ELECTRICALS 80-55452-00 CONDENSER ASSEMBLY 80-55453-00 CONDENSER FAN MOTOR 80-54014-00 DISPLAY MODULE 80-55429-00 DOOR ASSEMBLY 80-55505-00 DRAIN PAN 80-54217-00 DRIER 80-54055-00 EVAPORATOR ASSEMBLY 80-55486-00 EVAPORATOR COVER 80-55485-00 EVAPORATOR FAN W/COVER...
  • Page 31 Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 32 Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
  • Page 33 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
  • Page 34 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
  • Page 35 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
  • Page 36 USER GUIDE u-line.com System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold...
  • Page 37 USER GUIDE Compressor Specifications FMXA9C REFRIGERANT R600A DANGER VOLTAGE 230 VAC FREQUENCY 43-134 Hz START WINDING 20 Ohm at 77 Electrocution can cause death or serious injury. RUN WINDING 20 Ohm at 77 Burns from hot or cold surfaces can cause serious injury.
  • Page 38 Condenser Fan: Air moving through a condenser may be heard. Included in this section are some diagnostic tips; if additional help is required, please contact the U-Line • Automatic Defrost Drain Pan: Water may be heard Corp, “Customer Care Facility” at +1.414.354.0300 for dripping or running into the drain pan when the unit is assistance.
  • Page 39 USER GUIDE TROUBLESHOOTING GUIDE Concern Potential Causes Action Not Cooling Compressor overheating Verify proper air flow through condenser. Is condenser clean? Confirm condenser fan operation. Compressor not operating Test overload and relay, replace as needed. Compressor operating - no cooling Refer to System Diagnosis Guide.
  • Page 40 USER GUIDE MAIN CONTROL CAUTION The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose Precautions must be taken while working with the board for any suspected failures before attempting live electrical equipment.
  • Page 41 USER GUIDE Control Operation-Service CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS UI BUTTON LAYOUT and release Unit will immediately Press ON/OFF turn ON or OFF Sabbath Mode See “Sabbath Mode” section Hidden Button SHOWROOM MODE -Access Service Menu This mode is designed to show units in a display -No LED directly above.
  • Page 42 USER GUIDE SERVICE MODE GUIDE SERVICE MODE GUIDE 0. Exit THERMISTOR 1 — ZONE 1. Thermistor 1 temperature not including offsets. This shows the pure thermistor reading with no offsets 2. Thermistor 2 temperature not including offsets. taken into account. 3.
  • Page 43 See Model list table. Push and hold the U-Line button. 22. LIGHT ALL LED SEGMENTS While still holding the U-Line button, plug the unit into This will illuminate all the LEDs on the display to the appropriate power source.
  • Page 44 USER GUIDE Control Operation-Service...
  • Page 45 USER GUIDE Thermistors provide reliable temperature readings preset defrost timer during defrost cycles. The unit will u-line.com using a resistance which varies based on surrounding otherwise operate normally. Refer to defrost section. temperatures. If a faulty thermistor is suspected it may be tested using an accurate ohmmeter.
  • Page 46 USER GUIDE Defrost This unit defrosts, by default, every 12 hours of compressor runtime for 45 minutes. If you have verified that the unit does not have an ambient air leak, refer to the Control Operation - Service section and adjust unit to defrost every 9 hours for 60 minutes.
  • Page 47 USER GUIDE Remove Fan and Cover Remove insulating foam from refrigerant line pass- through hole as needed to gain clearance for fan plug. CONVECTION COOLING Remove internal shelving. This unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, Remove 8 evaporator cover screws.
  • Page 48 USER GUIDE NOTICE Fan must be oriented to pull air in through lower evaporator cover vents and push air out at fan mounting location. 13. Installation is the reverse of removal. 14. Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge of the train trough.
  • Page 49 For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.