Massey GC1725m Cab
This ROPS cab is designed and built
to fit the Masey Ferguson GC1712E
and GC1725M tractor.
Designed and Built by:
Tektite Manufacturing Inc:
427 Buffalo Street
P.O. Box 639
Winkler, MB
R6W 4A8
Canada
PH: 204-331-3463
Fax: 204-331-4159
sales@tektite.ca
One year standard product
warranty provided by Tektite.
www.tektite.ca

Advertisement

loading
Need help?

Need help?

Do you have a question about the Massey GC1725M ROPS Cab and is the answer not in the manual?

Questions and answers

Summary of Contents for Tektite Massey GC1725M ROPS Cab

  • Page 1 May 2019© Massey GC1725M ROPS Cab Operator Manual Massey Ferguson GC1725M Cab Massey GC1725m Cab ** Shown with optional equipment This ROPS cab is designed and built to fit the Masey Ferguson GC1712E and GC1725M tractor. Designed and Built by:...
  • Page 2 Massey GC1725M ROPS Cab Operator Manual Tektite Manufacturing Incorporated thanks you for purchasing a Massey Ferguson GC1725M ROPS cab! Tektite has worked very hard to design and build this ROPS product and we hope that it provides you with many years of ROPS protection.
  • Page 3 “as is” basis; c) wiper blades, light bulbs, fuses, clear vinyl or other consumables; d) glass where the point of failure has not been preserved intact and delivered to Tektite for analysis of the cause of the failure;...
  • Page 4: Safety Precautions

    May 2019© Massey GC1725M ROPS Cab Operator Manual Safety Precautions Safety First Read these instructions carefully. It is essential that you read the instructions and safety regulations before you attempt to assemble or use the features that are on this cab/ROPS.
  • Page 5: General Safety

    May 2019© Massey GC1725M ROPS Cab Operator Manual General Safety 1. Never let an unqualified or untrained driver operate the tractor. 2. Keep a fire extinguisher, with ABC rating securely fastened in the ROPS. Maintain it and be familiar with its use.
  • Page 6: Maintenance Safety

    May 2019© Massey GC1725M ROPS Cab Operator Manual Safe Operation on Rough Terrain 1. Drive the tractor slowly on hillsides and curves to eliminate the danger of tipping. Avoid slopes which are too steep for safe operation. Avoid sharp uphill turns.
  • Page 7 3. New ROPS decals and tractor decals are available from your tractor dealer. ROPS Safety 1. Install the ROPS in accordance with Tektite mounting instructions. Failure to do so may affect the ROPS ability to withstand a roll over. 2. If the ROPS is subjected to alteration, structural damage or involved in an over turn accident, the entire structure must be replaced.
  • Page 8 May 2019© Massey GC1725M ROPS Cab Operator Manual Operating Instructions Important The following section locates, identifies and briefly describes the functions of all cab controls. All operators should familiarize themselves with control location and function prior to operating the tractor. Failure to do so may result in unsafe operation of the tractor and possible injury or death to operators and bystanders.
  • Page 9 Standard and optional features are individually fused, and the fuses can be accessed behind the plug in the middle of the switch-plate. Cab Circuit Protection The Tektite ROPS cab is wired to provide maximum protection against individual circuit overload. All optional components are fused internally behind the cab switch plate. GC1725M Cab The GC1725M cab is designed to provide ROPS protection along with reasonable winter weather protection.
  • Page 10 Massey GC1725M ROPS Cab Operator Manual After your ROPS Cab has been installed: Before starting a tractor equipped with a Tektite ROPS cab: 1. Clear the operator platform of all tools. Tools left in or around the ROPS and tractor can cause operator interference which could lead to bodily injury and/or damage the machine.
  • Page 11 Daryl Furkalo 2019-06-03 transmitted. The material remains the property of specified Tektite and shall be returned upon request. The Checked By: Date: Size: material may not be reproduced or disclosed to third M06-0025 X.X =...
  • Page 12 Daryl Furkalo 2019-06-03 transmitted. The material remains the property of specified Tektite and shall be returned upon request. The Checked By: Date: Size: material may not be reproduced or disclosed to third M06-0012 X.X =...
  • Page 13 Daryl Furkalo 2019-06-03 transmitted. The material remains the property of specified Tektite and shall be returned upon request. The Checked By: Date: Size: material may not be reproduced or disclosed to third M06-0024 X.X =...
  • Page 14 Daryl Furkalo 2019-06-03 transmitted. The material remains the property of specified Tektite and shall be returned upon request. The Checked By: Date: Size: material may not be reproduced or disclosed to third M06-0011 X.X =...
  • Page 15 Daryl Furkalo 2019-06-03 transmitted. The material remains the property of specified Tektite and shall be returned upon request. The Checked By: Date: Size: material may not be reproduced or disclosed to third M06-0013 X.X =...
  • Page 16 Daryl Furkalo 2019-06-03 transmitted. The material remains the property of specified Tektite and shall be returned upon request. The Checked By: Date: Size: material may not be reproduced or disclosed to third M06-0014 X.X =...
  • Page 17 Imp. Daryl Furkalo 2013-07-05 transmitted. The material remains the property of specified Tektite and shall be returned upon request. The Checked By: Date: Size: material may not be reproduced or disclosed to third X.X = 1/16"...
  • Page 18 Daryl Furkalo 2019-06-04 transmitted. The material remains the property of specified Tektite and shall be returned upon request. The Checked By: Date: Size: material may not be reproduced or disclosed to third X.X =...