Figure 68
3. Lower and secure the operator's seat.
4. Replace the return filter at the right side of the machine
(Figure
68).
5. Start the engine and let it run for about 2 minutes to
purge air from the system. Shut off the engine and
check for leaks.
Checking the Hydraulic Lines
and Hoses
Service Interval: Before each use or daily
Inspect the hydraulic lines and hoses daily for leaks, kinked
lines, loose mounting supports, wear, loose fittings, weather
deterioration, and chemical deterioration. Make all necessary
repairs before operating the machine.
58