NOTES ON THIS DOCUMENT ......................Fehler! Textmarke nicht definiert. SAFETY, INSTALLATION AND USE....................... Fehler! Textmarke nicht definiert. OTHER USE INSTRUCTIONS......................Fehler! Textmarke nicht definiert. SCOPE OF DELIVERY .......................... Fehler! Textmarke nicht definiert. TECHNICAL DATA ..........................Fehler! Textmarke nicht definiert. ASSEMBLY............................Fehler! Textmarke nicht definiert. REQUIREMENTS ...........................
Page 3
Before installing and using the wallbox, the instructions must be read and understood in full by the installer and each user. Please keep the manual for the entire service life of the wallbox in order to be able to access it later. Also observe the operating instructions for your electric vehicle.
Page 4
Please contact the manufacturer of the defibrillator or pacemaker for further information. Improper use can cause serious injury or death, as well as destroy the vehicle or the charging station • Wallbox ALPHA DUO with RFID module and RS 485 interface • •...
Page 5
ALPHA – NRG1006 Charging power mode 3 [kW] per 3.7 (1-phase) / 11 (3-phase) output 7.4 (1-phase) / 22 (3-phase) Charging power mode 3 [kW] total Nominal voltage UN [V] 50Hz 230 (1-phase) / 400 (3-phase) max. line protection [A] Residual current protection/disconnecting device AC [mA]...
Page 6
The wallbox may only be installed by a trained electrician. Before installation, the device must be thoroughly checked for damage. The wallbox is only suitable for vertical installation. The box may be mounted indoors or in protected outdoor areas, such as under canopies. The ambient temperature at the installation site must be in the range of -20°C to +40°C.
Page 7
The supply line of the wallbox must be disconnected from the power supply during installation work. The supply line must be correctly fused. 1. Pull the supply line into the box 2. Connect the supply line as shown in Figure 2 and then relieve the strain and seal it using the cable gland. Figure 2 Connection position of the supply line Check the electrical connection and voltages using a measuring device.
Page 8
When using RS485, a double line with a characteristic impedance of 120 Ohm must be used. Since this is a data bus, it must be terminated with a resistor at the end or beginning. This can be done with the resistor pre-mounted in the interface or with the termination functions of other Modbus accessories.
By setting an additional jumper to FUNCTION 1, simultaneous loading of the vehicles is prevented. Loading now takes place one after the other. The vehicle that first makes the request to load is served first. The second vehicle can only be charged after the charging request has been dropped.
Page 10
This charging station is suitable for electrically charging one or two vehicles with type 2 charging couplings. By programming an RFID card (see "Programming RFID cards"), charging is only possible for authorized persons. If no RFID card is programmed, the wallbox is freely accessible. Pay attention to your safety when operating inside the wallbox and do not touch any live components.
Page 11
To use the RFID module, it is necessary to teach in at least one RFID card. RFID cards are taught as follows: 1. Open the wallbox with the key provided for this purpose. 2. Press and hold the Learn button on the RFID module and place the card to be learned on the right outside of the wallbox.
Page 12
In both cases, the charging process starts automatically. Charging points to which no vehicle is connected are locked by the wallbox after 30 seconds. As long as the connected vehicle is in the waiting or charging state, the connected charging point remains unlocked. After completion of the charging process, the charging point in use is also locked.
Page 13
The RS 485 interface communicates with Modbus RTU, 9600 baud, 8 DATA bits, 1 stop bit, parity none, slave ID 1, unsigned integer 16bit (UINT16, internal values 8 bit). The timeout is less than 2000ms. Register type 40XXX read and write, register type 30XXX read only. Modbus Modbus Initial value...
Page 14
Both charging points locked (0b11) Information about RFID cards can be requested depending on the software version at support@pracht.com. In the event of a defect, please contact the manufacturer directly. Before cleaning, the wallbox must be disconnected from the power supply for safety reasons.
Page 15
Restart the charging process. To do this, disconnect the The loading process was canceled. • connection between the wallbox and the vehicle for 10 seconds. PRACHT Industry GmbH Am Seerain 3, 35232 Dautphetal-Buchenau, Germany Tel. +49 6466 9140-900 info@prachtenergy.com, www.prachtenergy.com...