ACS 601.86861.00 Operation And Instruction Manual page 45

Advanced microprocessor controller
Table of Contents

Advertisement

Modbus Accessible Parameter Mapping. The customized controller allows access to (29)
controller parameters and settings, which can be accessed in Integer Mode or Floating point
mode. This is accomplished with (2) Point Address ranges, allowing data exchange in either
integer or floating point format, for all controller parameters and settings. All data conversion
such as rounding, integer float, Etc, is transparent and handled by the controllers, since
internal variables data type can be different for the MODBUS data exchange types.
The M2C Advanced controllers is customized controller software supports the following
Modbus Parameters and Settings:
Figure 4: Modbus Parameters List
Parameter
/ Item
Menu
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
30
31
32
M2C Advanced
R/W Integer
Float
Data
Data
Region
Region
Point
Point
Address
Address
R
0000
4000
R
0001
4002
R
0002
4004
R
0003
4006
R
0004
4008
R/W
0005
4010
R/W
0006
4012
R/W
0007
4014
R/W
0008
4016
R/W
0009
4018
R/W
0010
4020
R/W
0011
4022
R/W
0012
4024
R/W
0013
4026
R/W
0014
4028
R/W
0015
4030
R/W
0016
4032
R/W
0017
4034
R/W
0018
4036
R/W
0019
4038
R/W
0020
4040
R
0021
4042
R/W
0022
4044
R/W
0023
4046
R/W
0024
4048
R/W
0025
4050
R/W
0026
4052
R/W
0027
4054
R/W
0028
4056
R
0030
4060
R
0031
4062
R
0032
4064
682.98769.00
Min
Max
Description
Value
Value
0
0
Version ID (4369)
-34
343
Delivery Temp (ºC)
-34
343
Mold Temp (ºC)
-34
343
Return Temp (ºC)
0
999
Flow Value
0
1
System Standby Heat/cool
0
1
Temp Units
-34
343
Setpoint 1 (ºC)
-34
343
Setpoint 2 (ºC)
-34
343
Alarm 1 Low (ºC)
-34
343
Alarm 1 High (ºC)
1
343
Prop. Band Heat (ºC)
1
343
Prop. Band Cool (ºC)
0
999
Reset (seconds)
0
999
Rate (seconds)
0
999
Autotune.State
0
999
Autotune.TuneDutyPercent
0
999
Autotune.PeakOverShoot
0
999
Autotune.PeakUnderShoot
0
999
Autotune.InitialTempDeviation
0
999
Autotune.ProcessTripTemp
-34
343
Delivery Temp (ºF)
-34
343
Setpoint 1 (ºF)
0
999
Proportional Percent (%)
0
999
Integral Percent (%)
0
999
Direvative Percent (%)
0
999
PID Output Percent (%)
0
999
Heater Output Percent (%)
0
999
Cooling Output Percent (%)
0
1
Pump Status
0
1,2,3
Heater Status; 1=low, 2=high,
3=low & high
0
1
Vent Status
• 8/24/18