(14)
Fig. 6&7
Schémas 7 et 8
HOW TO INSTALL THE WINDOW SEAL KIT
The window seal kit is included in the reference AU5020F0. It can be bought as a Rowenta accessory
with reference XD6620F0 (#16). Before installation, check that the adhesive gripping tape do not dam-
age your window.
1. Open the window and clean the surfaces to remove dust and grease on the
window frame and casement.
Stick the strip to the frame. Do not stick it to the contact surface of the window
seal (you must be able to close the window).
2. Stick the strip to the outside or inside of the window casement (handle side).
Ensure that the window can be closed.
Before sticking together, make sure the sticky surface does not damage the
window frame.
3. Leave the window open. First stick the wide side of the window form (zip
closed) from the center to the right and left hand sides or to the top and bottom
to the window frame.
4. Close the window and make sure that it does not clamp the window form.
Stick the narrow side of the window form (zip closed) from the center to the
right and left hand sides or to the top and bottom to the casement.
5. Open the window slightly to have the exhaust hose into the window form by
using the zipper.
MAX 100 cm
(16)
MIN 35 cm
(16)
(16)