Gas Consumption - Baxi 941 Owner's Manual

Inset live fuel effect gas fire
Table of Contents

Advertisement

OWNER GUIDE
Do provide a suitable guard that complies with BS 8423 for the protection of young
children, the elderly and the infirm. Such a guard is also recommended for the
protection of pet animals. (Although this fire conforms to all the applicable standards, it
is a heating appliance and certain parts of its surface will become hot).
Do wait three minutes before attempting to relight if the fire is switched off or the
flames are extinguished for any reason. (Your fire is fitted with a safety device that will
automatically shut off the gas supply to the fire if, for any reason, the flames go out).
Do get advice about the suitability of any wall covering near your fire. Soft wall
coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected by
heat. They may, therefore, scorch or become discoloured when close to a heating
appliance. Please bear this in mind whenever you are considering redecorating.
Do provide a minimum side clearance as detailed in figure 1. Please bear this in mind if
ever you are considering altering the room.
Don't hang clothing, towels or any other fabrics over the fire.
Don't add any extra fuel effect pieces above the number stated in the installer and
owner guide supplied with the ceramics. This may have been placed inside or attached
to this guide. Also, do not use any ceramic fuel effect pieces other than those authorised
for this fire. This could cause incomplete combustion and subsequent safety hazard.
Don't put paper or any other material on the fire.
Don't place any combustible material (rugs, carpet, plastic tiles, etc.) on the hearth.
Don't attempt to clean or service the fire until it has been switched off and allowed to
cool completely.

GAS CONSUMPTION

Model 941
Has a maximum natural gas input of 6.8kW (Gross)
Has a maximum natural gas output of 3.5kW
Has a minimum natural gas input of 2.3kW (Gross)
Has a minimum natural gas output of 0.90kW
Model 941 when converted using kit number 0595211
Has a maximum propane gas input of 6.7kW (Gross)
Has a maximum propane gas output of 3.7kW
Has a minimum propane gas input of 4.0kW (Gross)
Has a minimum propane gas output of 2.1kW
©