Gas Connection; Adapting To Different Types Of Gas - Whirlpool GOA 7523/NB1 Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
styrofoam parts etc.) must be stored out of reach of
children - risk of su ocation. The appliance must be
disconnected from the power supply before any
installation operation - risk of electrical shock. During
installation, make sure the appliance does not damage
the power cable - risk of re or electrical shock. Only
activate the appliance when the installation has been
completed.
WARNING: Modi cation of the appliance and its
method of installation are essential in order to use
the appliance safely and correctly in all the additional
countries.
Use pressure regulators suitable for the gas pressure
indicated in the instruction.
The room must be equipped with an air extraction
system that expels any combustion fumes.
The room must also allow proper air circulation, as
air is needed for combustion to occur normally. The
ow of air must not be less than 2 m
installed power.
The air circulation system may take air directly from
the outside by means of a pipe with an inner cross
section of at least 100 cm
vulnerable to any type of blockages.
The system can also provide the air needed for
combustion indirectly, i.e. from adjacent rooms tted
with air circulation tubes as described above. However,
these rooms must not be communal rooms, bedrooms
or rooms that may present a re hazard.
Liquid petroleum gas sinks to the oor as it is heavier
than air. Therefore, rooms containing LPG cylinders
must also be equipped with vents to allow gas to escape
in the event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or
stored in rooms or storage areas that are below ground
level (cellars, etc.). It is advisable to keep only the cylinder
being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens,
replaces, stoves, etc. ) which could raise the temperature
of the cylinder above 50°C.
Should you experience di culty in turning the burners knobs, please contact
After Sales Service for replacement of the burner tap if found to be faulty.
The openings used for the ventilation and dispersion of heat must never be
covered.
Carry out all cabinet cutting works before tting the
appliance in the furniture and remove all wood chips
and sawdust.
If the appliance is not installed above an oven, a
separator panel (not included) must be installed in the
compartment under the appliance.

GAS CONNECTION

WARNING: Prior to installation, ensure that the local
distribution conditions (type of gas and gas pressure)
and the adjustment of the appliance are compatible.
Check that the pressure of the gas supply is consistent
with the values indicated in "Burner and nozzle
speci cations" table.
/h per kW of
3
; the opening must not be
2
WARNING: The con guration conditions for this
appliance are stated on the label (or data plate).
WARNING: This appliance is not connected to a
combustion products evacuation device. It must be
installed and connected in accordance with current
installation regulations. Particular attention must be
paid to the relevant requirements regarding ventilation.
If the appliances is connected to liquid gas, the
regulation screw must be fasted as tightly as possible.
IMPORTANT: When the gas cylinder or gas container is
installed, it must be properly settled (vertical orientation).
WARNING: This operation must be performed by a
quali ed technician.
Use only exible or rigid metal hose for gas connection.
Connection with a rigid pipe (copper or steel)
Connection to the gas system must be carried out in
such a way as not to place any strain of any kind on the
appliance. There is an adjustable L-shaped pipe tting
on the appliance supply ramp and this is tted with a
seal in order to prevent leaks. The seal must always be
replaced after rotating the pipe tting (the seal is
provided with the appliance). The gas supply pipe
tting is a threaded 1/2 gas cylindrical male attachment.
Connecting a exible jointless stainless steel pipe to
a threaded attachment. The gas supply pipe tting is a
threaded 1/2 gas cylindrical male attachment. These
pipes must be installed so that they are never longer
than 2000 mm when fully extended. Once connection
has been carried out, make sure that the exible metal
pipe does not touch any moving parts and is not
compressed. Only use pipes and seals that comply
with current National regulations.
IMPORTANT: If a stainless steel hose is used, it must
be installed so as not touch any mobile part of the
furniture (e.g. drawer). It must pass through an area
where there are no obstructions and where it is possible
to inspect it on all its length.
The appliance should be connected to the main gas
supply or to gas cylinder in compliance with the current
national regulations. Before making the connection,
make sure that the appliance is compatible with the gas
supply you wish to use. If this is not the case, follow the
instructions indicated in the paragraph "Adapting to
di erent types of gas".
After connection to the gas supply, check for leaks
with soapy water. Light up the burners and turn the knobs
from maximum position 1* to minimum position 2* to
check ame stability.

ADAPTING TO DIFFERENT TYPES OF GAS

(This operation needs to be carried out by a quali ed
technician).
In order to adapt the appliance to a type of gas other
than the type for which it was manufactured (indicated
on the rating label), follow the dedicated steps provided
after installation drawings.

Advertisement

Table of Contents
loading

Table of Contents