No. Part name
1. Detachment
Drain pump
1) Carry out works of item 1 of
2) Remove the drain pump connector (CN504, White, 2P)
connected to the control P.C. board and then remove
the lead wire from the clamp.
3) Remove the fixing screws and then remove the drain
pump. (DIA 4 × 10, 3 pcs.)
4) As shown in the right figure, first pull out the
connecting part of the drain pump and the drain hose
from the drain port and then take out the drain pump.
5) Set direction of the knob of the hose band downward,
slide it from the pump connecting part to the hose side
and then remove the drain hose from the drain pump.
6) Pass the connector of the drain pump lead wire
through the wiring taking-out port and then take out
the drain pump.
2. Attachment
1) Put your hand into the drain port and pass the
connector of the drain pump lead wire through the
wiring taking-out port.
2) Connect the drain hose to the drain pump as before.
NOTE :
Insert the drain hose up to the end of the drain
pump connecting part, apply band to the white or
yellow mark position of the hose and then set the
band knob upward.
3) Return the drain pump to the indoor unit and then
mount it as before using the fixing screws.
(DIA 4 × 10, 3 pcs.)
4) Connect the drain pump connector (CN504, White, 2P)
to the control P.C. board and then fix it as before with
the clamp.
5) Following to words of item 2 of
mount the drain cap, the electric parts box cove and
the suction grille as before.
Procedure
and item 1 of
and item 2 of
– 95 –
Remarks
.
Fixed screw
Drain pump
Wiring outlet
CN504
Drain mouth
Clamp