Installation And Preparation For Use; Instructions For The Installer - Vento GE 6060 CS 6MT User Manual

Free standing cooker
Table of Contents

Advertisement

Available languages

Available languages

2. INSTALLATION AND
PREPARATION FOR USE
WARNING : This appliance must be
installed by an authorised service
person or qualified technician,
according to the instructions in this guide
and in compliance with the current local
regulations.
Incorrect installation may cause harm
and damage, for which the manufacturer
accepts no responsibility and the
warranty will not be valid.
Prior to installation, ensure that the local
distribution conditions (electricity voltage
and frequency and/or nature of the gas
and gas pressure) and the adjustments
of the appliance are compatible. The
adjustment conditions for this appliance
are stated on the label.
The laws, ordinances, directives and
standards in force in the country of use
are to be followed (safety regulations,
proper recycling in accordance with the
regulations, etc.).
If the product contains removable shelf
guides (wire racks) and the user manual
includes recipes like yoghurt, the wire
racks shall be removed and the oven
operated in the defined cooking mode.
Removal of the Wire Shelf information
is included in the CLEANING AND
MAINTENANCE section.

2.1 inStruCtionS for the inStaller

Ventilation requirements
For rooms with a volume of less than
5 m
, permanent ventilation of 100 cm
3
free area is required.
For rooms with a volume of between 5
m
and 10 m
, permanent ventilation of
3
3
50 cm
free area will be required, unless
2
the room has a door which opens
directly to outside air in which case no
permanent ventilation is required.
For rooms with a volume greater than
10 m
, no permanent ventilation is
3
required.
Important: Regardless of room size, all
rooms containing the appliance must have
direct access to outside air via an openable
window or equivalent.
Emptying of burned gases from the
environment
Gas appliances expel burned gas waste
to the outside air, either directly or via a
cooker hood with a chimney. If it is not
possible to install a cooker hood, install a
fan on the window or wall that has access
to fresh air. The fan must have the capacity
to change the volume of air in the kitchen a
minimum of 4-5 times per hour.
2
General instructions
After removing the packaging material
from the appliance and its accessories,
ensure that the appliance is not
damaged. If you suspect any damage,
do not use it and contact an authorised
service person or qualified technician
immediately.
EN - 12
Air inlet section
min. 100 cm
2
Air inlet section
min. 100 cm
2
Cooker
hood
flue
Air inlet section
min. 100 cm
2
Electrical ventilator
Air inlet section
min. 100 cm
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ge 6060 cs 6mt xGe 6060 cs 6mt wh

Table of Contents