9-8. FUNCTIONS OF DIP SWITCH AND JUMPER WIRE
Each function is controlled by the DIP switch and the jumper wire on the indoor controller board.
Jumper wire
Functions
Model
SW1
settings
Capacity
SW2
settings
Pair number
setting with
J41
wireless
J42
remote
controller
TCH117
Setting by the DIP switch and jumper wire
MODELS
SETTING
1 2 3 4 5 6
PKA-A ・ LA1
MODELS
SETTING
1 2 3 4 5
6
PKA-A12LA1
1 2 3 4 5
6
PKA-A18LA1
Control PCB setting
Wireless remote
controller setting
J41
0
1
2
3–9
Jumper wire (
: Short
25
The black square (
ON
OFF
ON
OFF
ON
OFF
<Initial setting>
Wireless remote controller: 0
Control PCB:
J42
4 pair number settings are supported.
The pair number settings of the wireless remote
controller and indoor control PCB (J41/J42) are
given in the table on the left.
(' ' in the table indicates the jumper wire is dis-
connected.)
: Open)
) indicates a switch position.
Remarks
(for both J41 and J42)