Ruck Ventilatoren 145815 Installation, Operating And Maintenance Instruction

Ruck Ventilatoren 145815 Installation, Operating And Maintenance Instruction

Smoke extract fan for exhaust air applications

Advertisement

Quick Links

Installation, operating and maintenance instructions
English
MPS...D.F4
Example configuration shown
CONTENTS
FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.
IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.
GENERAL SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.
ADHERE TO THE FOLLOWING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.
PRODUCT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.
DELIVERY CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.
TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7.
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8.
9.
TRANSPORT AND STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
10.
ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
11.
ELECTRICAL CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
12.
COMMISSIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
13.
MAINTENANCE AND CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
14.
LIFETIME AND DISPOSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
15.
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
16.
ruck Ventilatoren GmbH
Max-Planck-Str. 5
D-97944 Boxberg-Windischbuch
Tel.
+49 (0)7930 9211-300
Fax
+49 (0)7930 9211-166
info@ruck.eu
www.ruck.eu
Smoke extract fan
for exhaust air
applications
The original instructions were created in the German language.
2018
. . . . . .
9
Information updated
print 26.06.2019
Subject to change
www.ruck.eu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 145815 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ruck Ventilatoren 145815

  • Page 1: Table Of Contents

    TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 ruck Ventilatoren GmbH Max-Planck-Str.
  • Page 2: Foreword

    FOREWORD Dear customers, Thank you for choosing our device. Before operating the unit, please read carefully these installation, operating and maintenance instructions. If you have any questions, please contact: (Contact details see page 1) The data provided in these installation, operating and maintenance instructions are for the product description only. A statement about a certain condition or a suitability for a certain application cannot be derived from our information.
  • Page 3: General Safety Instructions

    2.2. Provisions and regulations When properly installed and operated, the device complies with the applicable standards and EU Directive at the time of its placing on the market. In addition, observe generally valid, legal and other binding regulations of the European or national legislation as well as the regulations in your country for accident prevention and environmental protection.
  • Page 4 3.1. Intended use Our devices are incomplete machineries as defined in the EU Machinery Directive 2006/42/EC (partly completed ma- chinery). The product is a not ready-for-use machine in terms of the machine directive. It is intended exclusively for installation in a machine or in ventilation equipment and installations or for combination with other components to form a machinery or installation.
  • Page 5 Safety sign (warning Consequence triangle) General warning! Indicates possible hazardous situations. Failure to observe the warnings may result in perso- nal injury and / or damage to property. Electricity warning (hazardous voltage)! Indicates possible hazards due to electricity. Failure to observe the warnings may result in death, injury and/or damage to property.
  • Page 6: Adhere To The Following Instructions

    ADHERE TO THE FOLLOWING INSTRUCTIONS 4.1. General instructions ■ Persons who assemble, operate, disassemble or maintain our devices must not be under the influence of alcohol, drugs or pharmaceuticals that may affect perception and responsiveness. ■ Responsibilities for the operation, maintenance and regulation of the product should be clearly determined and observed so that there can be no unclear areas of responsibility with regard to safety.
  • Page 7: Delivery Contents

    ■ The assembled mounting rails are additionally equipped with rubber vibration dampers, which can also be repositi- oned on the housing and thereby allow three discharge direction. 5.1. Permissible conveying medium temperatures perm. temperature / time perm. temperature in in smoke extraction continuous operation Series ■...
  • Page 8: Technical Data

    TECHNICAL DATA Product name °C °C dB(A) dB(A) dB(A) MPS 225 D2 F4 30 145815 400V 3~Y 141262 29,3 MPS 250 D2 F4 30 145819 400V 3~Y 141262 38,0 MPS 280 D2 F4 30 145832 400V 3~Y 141262 38,5 MPS 315 D2 F4 30...
  • Page 9: Data In Accordance With Erp Directive 327/2011 Of The European Parliament

    ! Year of manufacture see nameplate Manufacturer name / Commercial registration number / Place of establishment ruck Ventilatoren GmbH / Local District Court Mannheim HRB 560366 / Germany Nominal motor power input at optimum energy efficiency point P [kW] 0,33...
  • Page 10: Transport And Storage

    10. TRANSPORT AND STORAGE Transport and storage should only be performed by specialist personnel in accordance with the assembly and opera- ting manual and regulations in force. The following points should be noted and followed: ■ Check the delivery according to the delivery note to ensure it is complete and correct and check for any damage. Any missing quantities or damage incurred during transport should be confirmed by the carrier.
  • Page 11: Assembly

    11. ASSEMBLY Assembly work may only be performed by specialist personnel in accordance with the installation and operating ma- nual and the regulations and standards in force. The following points should be noted and followed: ■ The foundation must be even and levelled. It must not exhibit unevenness or a slope in any direction. ■...
  • Page 12 11.3. Assembly with discharge on side ■ Release handle (1), hinges (2) and screwed connections (3) C. Discharge left ■ Turn the device completely D. Discharge right ■ Mount hinges (2) on the right ■ Turn the device completely ■ Mount handle (1) in position as ■...
  • Page 13: Electrical Connection

    12. ELECTRICAL CONNECTION • Electricity warning (hazardous voltage)! » Failure to observe the hazard may result in death, injury or damage to property. → Before performing any work on conductive parts, always disconnect the unit completely from the electri- city supply and make sure that it cannot be switched back on again. The electrical installation may only be carried out by qualified electricians in compliance with the installation, operating and maintenance instructions and the applicable national regulations, standards and guidelines: ■...
  • Page 14 12.2. Star circuit / Delta circuit ■ Star circuit In star connection, the terminals U2, V2 and W2 are connected by the shorting blades. In order to get a right turning field L1 has to be connected to U1, L2 to V1 and L3 to W1.
  • Page 15: Commissioning

    Frequency f Frequency f Max. motor current I Max. motor current I 3~400V Y 3~230V D MPS 225 D2 F4 30 145815 MPS 250 D2 F4 30 145819 MPS 280 D2 F4 30 145832 MPS 315 D2 F4 30 145840...
  • Page 16 Our devices require little maintenance when operated properly. The following work should be performed at regular intervals, in accordance with health and safety regulations: ■ Check the operation of the control system and safety devices. ■ Check electrical connections and wiring for damage. ■...
  • Page 17 14.3. Impeller installation with Taperlock clamping bush The impeller is connected by means of the clamping bush to the shaft end of the drive motor. Assembly 1. Clean all bare surfaces (mating surfaces of the clamping bushings and motor shaft). 2.
  • Page 18: Lifetime And Disposal

    15. LIFETIME AND DISPOSAL 15.1. Product life The motors are equipped with maintenance-free, permanently lubricated ball bearings. Under normal operating condi- tions, the expected lifetime is about 30,000 operating hours. The information given here depends strongly on the respective field of application as well as the environmental condi- tions.
  • Page 19 Notes www.ruck.eu |...
  • Page 20 Ventilatoren GmbH Max-Planck-Str. 5 D-97944 Boxberg-Windischbuch Tel. +49 (0)7930 9211-300 +49 (0)7930 9211-166 info@ruck.eu www.ruck.eu Information updated print 26.06.2019 mpsg_pb_04_en We reserve the right to make changes Language: English...

Table of Contents