Salicru BM-R 63 A User Manual

Rack mounting manual bypass bm-r 3, 6 and 10 kva
Hide thumbs Also See for BM-R 63 A:

Advertisement

Quick Links

USER'S MANUAL
RACK MOUNTING MANUAL BYPASS
BM-R 3, 6 and 10 kVA

Advertisement

Table of Contents
loading

Summary of Contents for Salicru BM-R 63 A

  • Page 1 USER'S MANUAL RACK MOUNTING MANUAL BYPASS BM-R 3, 6 and 10 kVA...
  • Page 2 SALICRU...
  • Page 3 General index. 8. MAINTENANCE, WARRANTY AND SERVICE. 1. INTRODUCTION. 8.1. MAINTENANCE. 1.1. THANK YOU LETTER. 8.2. WARRANTY CONDITIONS. 2. SAFETY INFORMATION. 8.2.1. Warranty terms. 2.1. USING THIS MANUAL. 8.2.2. Out of scope of supply. 2.1.1. Conventions and symbols used. 8.3. TECHNICAL SERVICE NETWORK. 2.2.
  • Page 4 We remain at your disposal for any additional information or queries that you may wish to make. Yours sincerely. SALICRU The equipment described herein is capable of causing • significant physical damage in the event of improper handling.
  • Page 5: Safety Information

    2.2. ADDITIONAL SAFETY PRECAUTIONS. The documentation of any standard equipment is available to In the point of view of installation and electrical safety, • (www.salicru. the customer on our website for download the rack mounting manual bypass must be considered as a com).
  • Page 6 (contact your distributor). Packaging: For the recycling of the packaging there must be compliance with the legal requirements in force, according to the specific regulations of the country where the equipment is installed. SALICRU...
  • Page 7: Product Definition

    4. OVERVIEW. 4.1. VIEWS. 4.1.1. Equipment front views. 4.1.2. Corresponding legend of the equipment's views. Fig. 1 and 2 show the corresponding illustrations of the rack AC power supply IEC connector or input terminals. mounting manual bypass, ready to be installed in 19" rack cabi- To be connected to the UPS or stabilizer input.
  • Page 8 RACK MANUAL BYPASS supply 40 / 63 A Output terminals to equipment loads input From equipment output EMBS connector Output UPS / STABILIZER terminals Equipment input to loads terminals Fig. 4. Wiring between UPS and 6 and 10 kVA bypass. SALICRU...
  • Page 9: Installation

    6. INSTALLATION. Read and respect the Safety instructions, described • in section 2 of this document. The fact of omitting any of the stated indications can cause serious or very se- rious accidents to the surrounding, as well as failures in the equipment and/or loads connected to it.
  • Page 10 Connect the main earth protection cable to the ter- minal ]. There is a second terminal beside the output terminals. The earth protection cable to be con- nected to the UPS or stabilizer can be taken from any of them. SALICRU...
  • Page 11: Ups» Mode

    7. OPERATING. UPS or stabilizer operating manual, which the manual by- In case the UPS or stabilizer have not been transferred to • pass is linked has to be available. «Bypass mode», when the protection cover is removed, Make sure that all connections have been done properly the equipment will shift to this operating mode automati- •...
  • Page 12: Maintenance, Warranty And Service

    Also, it will not cover any compensation due to the incurred damages. 8.3. TECHNICAL SERVICE NETWORK. The coverage in both national and international markets for Technical Service and Support (T.S.S.), can be found in our Website. SALICRU...
  • Page 13: Technical Specifications

    9. ANNEXES. 9.1. TECHNICAL SPECIFICATIONS. Available power rates (kVA ) Input and output tipology Single phase / Single phase Male IEC connector or terminals, AC input power IEC connector 3 terminals (phase, neutral and PE) supply Female IEC connector or terminals, UPS or IEC connector 3 terminals (phase, neutral and PE) stabilizer power supply...
  • Page 14  : ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................SALICRU...
  • Page 15  : ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................USER'S MANUAL BM-R Rack mounting manual bypass...
  • Page 16 REF. EL106B01 REV. B CODE 401* Avda. de la Serra 100 08460 Palautordera BARCELONA Tel. +34 93 848 24 00 services@salicru.com SALICRU.COM The Technical Service and Support (T.S.S.) network, Com- mercial network and warranty information are available in website: www.salicru.com...

This manual is also suitable for:

Bm-r 40 aBm-r 16a698op000023698op000022698op000029

Table of Contents