  • Page 1 INSTALLATION GUIDE / USER MANUAL DSA500X4 • DSA750X4 Rev. 20220706...
  • Page 2: Technical Notices

    Technical and Safety Notices Please read the following important technical, safety Safety and Environmental Notices and environmental notices before installing and using Note: The intent of the lightning flash with arrowhead symbol your amplifier. in a triangle is to alert the user to the presence of uninsulated Technical Notices “dangerous”...
  • Page 3: Important Safety Instructions

    Technical and Safety Notices Important Safety Instructions Environmental Statement Read these instructions. This product complies with international Keep these instructions. directives, including but not limited to the Heed all warnings. Restriction of Hazardous Substances (RoHS) Follow all instructions. in electrical and electronic equipment, the Do not use this apparatus near water.
  • Page 4: Introduction And Overview

    This manual covers the features, installation and PDIF digital input, and either two or four outputs (Lo-Z mode), or one or two outputs (Hi-Z or Lo-Z BTL mode). Danley DSA functions of the Danley DSA500X4 and DSA750X4 amplifier model output channel counts and power outputs are models.
  • Page 5: Carton Contents

    2.1 Connections and Power Switching 3. Carton Contents Danley DSA signal input and output connections are Danley DSA amplifiers are shipped in a cardboard carton accomplished via RCA Phono and Euroblock style connectors. containing the amplifier unit, a mains cable appropriate for the A GPIO (General Purpose In/Out) Euroblock connector enables sales territory, an accessory pack, and a document pack.
  • Page 6: Installation

    (19 inch) equipment rack installation. If not to be installed in an equipment rack, Danley DSA amplifiers can be placed free-standing on a flat surface. Adhesive rubber feet are supplied for this purpose. It is important that any installation provides space for airflow through the ventilation apertures at the front and rear of the amplifier.
  • Page 7: Network Services

    Section 5.3. 5.1 Mains Power Connection 5.2.2 Wireless (WiFi) Network Connection To connect a Danley DSA amplifier to a TCP/IP network using a Danley DSA amplifiers incorporate a power factor corrected wireless connection (WiFi) follow the steps below.
  • Page 8: Configuration Menus

    Opening a web browser that is network connected to a sensitivity, and gain trim for each amplifier input channel. An Danley DSA amplifier initially displays the Control Web App internal pink noise source, provided for system testing and set Dashboard illustrated in Diagram 5a. The Dashboard is the up, can also enabled or disabled, and adjusted for gain via the ‘home’...
  • Page 9 • The Source menu option enables inputs to be assigned to Note: The number of individual outputs available for configuration zones. will depend on the Danley DSA amplifier model and the input, zone and output mode configuration. • The GPIO Volume Control option enables external volume control to be applied to individual zones.
  • Page 10 Configuration • The Speaker Preset menu enables a set of speaker Diagram 5f parameters to be adjusted, and preset configurations to be Speaker Preset import file selection created. • Speaker Presets can be simply applied to the selected amplifier output or imported, chosen from a library, exported or cleared.
  • Page 11 Configuration Diagram 5g Diagram 5h Speaker Preset applied Speaker Preset parameter adjustment • The Driver Alignment preset menu enables delay to be • The Output Mode preset menu enables individual amplifier applied to individual amplifier outputs. outputs to be switched off or configured for Lo-Z, Hi-Z or Lo-Z BTL modes.
  • Page 12 Configuration 5.3.5 Settings Tab The Settings Tab enables miscellaneous amplifier settings to be configured and installation data to be recorded. The Settings Tab provides access to further sub-menus. Diagram 5i illustrates the Settings Tab. • The System Information menu provides text fields for the recording of installation data.
  • Page 13 Configuration 5.4 Setup and Signal Routing Thanks to their network based configuration features, Danley DSA amplifiers offer considerable versatility in terms of sources, signal routing, installation zones and output modes. Inputs can be freely assigned to installation zones, and those zones assigned freely to the available amplifier outputs in either Lo-Z or Hi-Z modes.
  • Page 14 Note: Only dynamic microphones are suitable for connection. Phantom power for condenser microphones is not provided. Note: When configured in Lo-A BTL mode of Hi-Z mode Danley DSA amplifiers operate in ‘bridged’ mode where the output of • If necessary, adjust the input gain using the slider or up/ two channels is combined.
  • Page 15 5.5 GPIO Setup and Connection Diagram 5l GPIO Settings Menu Danley DSA amplifiers provide a GPIO socket that enables remote control of volume, standby, mute and trigger functions. The GPIO connector pin functions are described in the GPIO Settings menu illustrated in Diagram 5l. The connection of GPIO based remote volume control and standby/mute are illustrated in Diagram 5m and Diagram 5n respectively.
  • Page 16: Input Connection

    100V AC to 240V AC, 50/60Hz. Use the mains by default reflects the input to amplifier installation Zones A cable supplied with the amplifier. and B and is intended to be used for daisy-chaining Danley DSA Danley DSA amplifiers incorporate a front panel mounted amplifiers.
  • Page 17: Network Connections

    Connections 6.4 Speaker Cable Gauge Cable Gauge Table Lo-Z installations, 0.5dB attenuation. 2 Ω, 4 Ω & 8 Ω loads Danley DSA speaker connection cable gauge should be Max Cable Max Cable Max Cable Cable Cross chosen appropriately to reflect the type of installation.
  • Page 18 Connections Diagram 6b Balanced analog input cable connections. 5 mm Low-Z Mode 5 mm Diagram 6c Output cable connections. Hi-Z/BTL Modes 5 mm...
  • Page 19 Connections Diagram 6d GPIO cable connections. 5 mm The exclamation point printed next to the output terminals of the amplifiers is, in addition to the CLASS 2 WIRING text, intended to alert users to the risk of hazardous voltages. Output connectors that could pose a risk are marked with the exclamation point.
  • Page 20: Operation

    Audio will be heard from any connected speakers. • Disconnect the amplifier from mains power. Note: Danley DSA amplifiers will by default not wake from Standby • Press and hold the front panel power button while Mode unless an input signal is present, a network ‘ON’ command is simultaneously reconnecting mains power.
  • Page 21: Specifications

    Specifications Model DSA500X4 DSA750X4 Channels 4 x Lo-Z/2 x Hi-Z 4 x Lo-Z/2 x Hi-Z Output Power @ 2Ω 4 x 500 W (SE) 4 x 750 W (SE) 4 x 500 W (SE) 4 x 750 W (SE) Output Power @ 4Ω...