  • Page 1 INSTALLATION GUIDE/USER MANUAL DSA125X4 Rev. 20220706...
  • Page 2 Technical and Safety Notices Please read the following important technical, safety Safety and Environmental Notices and environmental notices before installing and using Note: The intent of the lightning flash with arrowhead symbol your amplifier. in a triangle is to alert the user to the presence of uninsulated “dangerous”...
  • Page 3: Important Safety Instructions

    Technical and Safety Notices Important Safety Instructions Environmental Statement Read these instructions. This product complies with international Keep these instructions. directives, including but not limited to the Heed all warnings. Restriction of Hazardous Substances (RoHS) Follow all instructions. in electrical and electronic equipment, the Do not use this apparatus near water.
  • Page 4: Introduction And Overview

    1. Introduction 2. Amplifier Overview Danley DSA power amplifiers have been designed Danley DSA125X4 amplifiers are half rack width, 1U format power amplifiers that can drive both conventional low to provide configurable, consistent and reliable high impedance (Lo-Z, 4Ω to 16Ω) loudspeakers and high impedance performance audio power amplification for residential, (Hi-Z, 70V/100V) transformer coupled loudspeakers.
  • Page 5: Carton Contents

    Ethernet network connection options are also provided. • Amplifier unit Danley DSA amplifiers have no mains power switch and are • Mains power cable operational as soon as mains power is connected via the IEC •...
  • Page 6 Overview Diagram 1a Danley DSA two channel amplifier dimensions. (Shaded area defines ventilation space.) 44 mm 1.7 in 80 mm 3.1 in 25 mm 1.0 in 213 mm 8.4 in 220 mm 8.7 in Diagram 1b Danley DSA four channel amplifier dimensions.
  • Page 7: Installation

    4. Installation Note: The rack mounting and desk/wall mounting components described and illustrated in Sections 4.1 to 4.3 are not supplied with Danley DSA amplifiers but are available to purchase as accessories. Contact your amplifier re-seller for more information. Diagram 3a 4.1 Danley DSA Mounting...
  • Page 8: Free-Standing

    Installation 4.2 Free-standing Diagram 4a Danley DSA If not installed in an equipment rack, Danley DSA amplifiers can with desk/wall Mounting Plate and adhesive feet. be placed free-standing on a flat surface. Adhesive rubber feet 2 positions and 4 positions.
  • Page 9: Network Services

    5.2.2 Wireless (WiFi) Network Connection 100V AC to 240V AC, 50/60Hz. Use the mains cable supplied To connect a Danley DSA amplifier to a TCP/IP network using a with the amplifier and connect it to a switched mains supply. wireless connection (WiFi) follow the steps below.
  • Page 10: Configuration Menus

    5.3.1 Input Tab The Input Tab provides naming, mono/stereo selection, Opening a web browser that is network connected to a Danley sensitivity, and gain trim for each amplifier input channel. An DSA amplifier initially displays the Danley DSA Control Web internal pink noise source, provided for system testing and set App Dashboard illustrated in Diagram 5a.
  • Page 11 Note:: The number of individual outputs available for configuration • The Source menu option enables inputs to be assigned to zones. will depend on the Danley DSA amplifier model and the input, zone and output mode configuration. • The GPIO Volume Control option enables external volume control to be applied to individual zones.
  • Page 12 Configuration • The Speaker Preset menu enables a set of speaker Diagram 5f parameters to be adjusted, and preset configurations to be Speaker Preset import file selection created. • Speaker Presets can be simply applied to the selected amplifier output or imported, chosen from a library, exported or cleared.
  • Page 13 Configuration Diagram 5g Diagram 5h Speaker Preset applied Speaker Preset parameter adjustment • The Driver Alignment preset menu enables delay to be • The Output Mode preset menu enables individual applied to individual amplifier outputs. amplifier outputs to be switched off or configured for Lo-Z or Hi-Z modes.
  • Page 14 Configuration 5.3.5 Settings Tab The Settings Tab enables miscellaneous amplifier settings to be configured and installation data to be recorded. The Settings Tab provides access to further sub-menus. Diagram 5i illustrates the Settings Tab. • The System Information menu provides text fields for the recording of installation data.
  • Page 15 Configuration 5.4 Setup and Signal Routing Thanks to their network based configuration features, Danley DSA amplifiers offer considerable versatility in terms of sources, signal routing, installation zones and output modes. Inputs can be freely assigned to installation zones, and those zones assigned freely to the available amplifier outputs in either Lo-Z or Hi-Z modes.
  • Page 16 Note:: Only dynamic microphones are suitable for connection. Phantom power for condenser microphones is not provided. Note: When configured in Hi-Z mode Danley DSA amplifiers operate in ‘bridged’ mode where the output of two channels is combined. • If necessary, adjust the input gain using the slider or up/ This means that the number of output channels available in Hi-Z down icons.
  • Page 17 5.5 GPIO Setup and Connection Diagram 5l GPIO Settings Menu Danley DSA amplifiers provide a GPIO socket that enables remote control of volume, standby, mute and trigger functions. The GPIO connector pin functions are described in the GPIO Settings menu illustrated in Diagram 5l. The connection of GPIO based remote volume control and standby/mute are illustrated in Diagram 5m and Diagram 5n respectively.
  • Page 18: Input Connection

    ‘Euro Block’ connectors. Ensure that speaker connection polarity is correct throughout the installation: Analog Inputs Danley DSA analog inputs are of line level format with a default In the case of Lo-Z speaker connections, positive (+) amplifier input sensitivity of +4dBu (full output voltage swing/sensitivity) terminals should always be connected to positive speaker in all output modes.
  • Page 19: Network Connections

    Connections 6.5 Speaker Cable Gauge Cable Gauge Table Lo-Z installations, 0.5dB attenuation. 4 Ω & 8 Ω loads Danley DSA speaker connection cable gauge should be Max Cable Max Cable Cable Cross chosen appropriately to reflect the type of installation.
  • Page 20 Connections Diagram 6b Diagram 6d Balanced analog input GPIO cable connections. cable connections. 5 mm 5 mm Diagram 6c Output cable connections. Low-Z Mode 5 mm Hi-Z Mode 5 mm The exclamation point printed next to the output terminals of the amplifiers is, in addition to the CLASS 2 WIRING text, intended to alert users to the risk of hazardous voltages.
  • Page 21: Operation

    Power sharing optimises the amplifier’s ability Note: Danley DSA amplifiers will not switch on from Standby to deliver maximum power into dynamic loudspeaker loads Mode unless an input signal is present, a network ‘ON’ command is when playing music programme material.
  • Page 22: Specifications

    Specifications Model DSA125X4 Total System Power 500 W Output Power @ 4/8Ω 4 x 125 W Output Power @ 2 x 250 W 70/100V* Powershare (up to) 2 x 250 W Across all channels** Power Consumption 150W 44 x 220 x 319 mm Dimensions (1.7 x 8.7 x 12.6 in)