Page 1
ARC-10 ARC-15 & Service Manual ARC-10 Arrakis Systems inc. Advanced Radio Console Talk Talk ARC-15 Arrakis Systems inc. Talk to Caller Advanced Radio Head Console Monitor & Headphone phone Input Select Talk Talk to Caller Head Monitor & Headphone phone...
Page 2
How to contact Arrakis Systems Arrakis Systems inc. is located at Arrakis Systems inc 6604 Powell Street Loveland, Colorado 80538 Business Hours: 8:00am - 4:30pm mountain time Contact: Voice: 970-461-0730 Fax: 970-663-1010 email: support@arrakis-systems.com web: arrakis-systems.com Having difficulty contacting Arrakis? Refer to the website at...
Page 3
S a f e t y I n s t r u c t i o n s 1. Read All Instructions. All safety and operating 16. A Product and Cart Combination should be the type of power supplied to your facility, instructions must be read before operating the consult your local power company.
Page 4
Hazard / Warning Label Identification C AU T I O N RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: SHOCK HAZARD - DO NOT OPEN AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE ANY COVER OR PANEL.
This console carries a manufacturer‘s warranty subject to the following guidelines and limitations: Except as expressly excluded herein, Arrakis Systems inc. (“Seller”) warrants equipment of its own manufacture against faulty workmanship or the use of defective materials for a period of one (1) year from date of shipment to Buyer. The liability of the Seller under this Warranty is limited to replacing, repairing or issuing credit (at the Seller’s discretion) for any equipment, provided that Seller is promptly notified in writing within five (5)
Page 6
General Repair Considerations WARNING The console should be repaired by qualified, professional, & experienced, audio technicians ONLY. Before beginning any type of repair or opening the console CALL Arrakis customer support for recommendations. DESIGNED FOR MODULAR PART REPLACEMENT The ARC series console is designed for modular replacement rather than repair. The power supply is external and plug in. The rotary faders are plug in. Most ICs are plug in, and a physical board layout is provided with descriptions of the functions of each IC.
ACCESSING THE INTERIOR OF THE VU METER PANEL The VU meter panel is opened by removing the screw at the left and right front of the panel. ACCESS SCREWS Arrakis Systems inc.
Page 8
Replacing Slide Faders, Switches, and other parts Slide faders and switches are soldered onto the PC board and should be replaced at the factory if at all possible. The procedure requires proper tools, and it can be difficult to remove the parts without damaging traces or pads on the PC board. Also, the switches are very sensitive to temperature and duration during the soldering process and can be electronically damaged or destroyed when being soldered.
Page 9
(3) The pot will now remove from the rear of the the knob front panel. (4) Unplug the pot from the motherboard. To put a new rotary fader in place: Reverse the removal procedure ARC-15 Arrakis Systems inc. Advanced Radio Console Talk Talk to Caller ARC-10 Arrakis Systems inc.
Page 10
1.10 Replacing ICs ICs must be replaced with care. Most ICs in the console are socketed so that they can be replaced. When replacing an IC, be careful to not bend legs under the IC or outside the socket. Be extremely careful to not shock an IC or the PC board with a static dis- charge.
Technical Questions Arrakis Systems maintains a staff of friendly broadcast engineers, design engineers, and technicians who have many years of in depth field experience in broadcast- ing. All of our technical resources are available to you to answer installation questions, solve problems, and repair equipment. If you have a question or problem, please feel free to call us.
Page 12
Further customer service will be denied until the defective parts are returned of paid for. Spare Parts (not provided with the ARC-10 or ARC-15 consoles) A spare parts kit may be provided with the console. These parts are provided in case of emergency failure and normal infant mortality. These parts, when used to replace failures, are not replaced under warranty.
Page 13
1.13 ARC-10 Electronic Block Diagram CHANNELS 1 & 2 Talk to TALK VU meter CONTROL ROOM Studio PL-PR-AL-AR-Q-TB LEFT MONITOR OUTPUT Logic Logic Logic to powered speakers Trim (-10dBu RCA phono) MIC INPUT Trim balanced (-50dBu, XLR) VU meter RIGHT...
Page 14
1.14 ARC-10 Parts Layout Note All unmarked ICs are NE5532 op amps CH 9 Mono Phone Phone Phone CH 8 CH 6 CH 5 CH 3 Mic 2 Mic 1 Power Logic Out (R) Out (L) phntm power Ch 9 In...
Page 15
ARC-10 Motherboard IDC Connector Diagrams 1.15 CN12- RS232 IDC Conn. 9 Pin D-sub Connector on Back Panel Not connected Data Carrier Detect (DCD/CD) Note 1: connects thru ribbon cable to rear Data Set Ready (DSR) panel 9 pin D-sub connector for...
Page 16
ARC-15 Electronic Block Diagram 1.16 MIC CHANNELS Talk to TALK VU meter CONTROL ROOM Studio PL-PR-AL-AR-Q-TB LEFT MONITOR OUTPUT Logic Logic Logic to powered speakers Trim (-10dBu RCA phono) MIC INPUT Trim balanced (-50dBu, XLR) VU meter RIGHT INTERNAL CUE SPEAKER 48V PHANTOM in VU meter bridge Trim...
Page 17
1.17 ARC-15 Parts Layout (10 channel main board) Note All unmarked ICs are NE5532 op amps CH 9 Mono Phone Phone Phone Ch14 CH13 CH12 CH11 CH10 CH 8 Mic5 Mic4 Power Logic Out (R) Out (L) phntm power Ch 14 In Unbal/USB USB Codec L L R R...
Page 18
Channel 2 Logic (not used in 15 pin D-sub) not used Note: connects to monitor, headphone and Note: connects thru ribbon cable to rear cue pots on front panel of console panel 15 pin D-sub connector ARC Console Board Connector Diagram Arrakis Systems Rev A 5/21/2007...
Page 19
1.19 ARC-15 Parts Layout (5 channel expansion board) Stereo Line Channel Inputs Mono Mic Channel Inputs CH 7 CH 6 CH 5 CH 4 CH 3 CH 2 Mic 3 Mic 2 Mic 1 Note All unmarked ICs are NE5532 op amps Stereo Line Channel Input Preamps CH 7 CH 6...
Page 20
1.20 ARC-15 VU Meter Driver PC Board 10pF 32.4K 4.7K 2.2K 5532 47uF Pgm R 10pF 32.4K 4.7K 2.2K 5532 47uF Pgm L MOTHER BOARD 10pF 32.4K 4.7K TO MOTHERBOARD TO VU METERS 2.2K 5532 47uF Aud L Pgm L Pgm R ground Aud L...
Page 21
PR (wo phone) AL (wo phone) AR (wo phone) CR Mic Logic To Caller Main Preamp Mixing Bus Summing Amps CR MIC P/A/Q/Mic CR Mic to Studio Monitor CR MUTE Logic ARC Console Main Buss Diagram Arrakis Systems Rev A 5/21/2007...
Page 27
-15 to +18dBu unbal 10uF DB15 47 ohm -9 to + 24dBu bal 5532 10uF From Pin 12 47 ohm Ch 1 Mic (Max out = +25dBu) (-2dB) Talkback Preamp audio out (+4dBu =3.5VPtoP) ARC Console Arrakis Systems Rev A 5/21/2007 Output Schematic...
Page 28
5532 .047uF NOTE #1: The meter circuits on the 10 channel 100K PC board are used for the ARC-10 only. The ARC-15 has VU meter driver boards located on (-)5VDC (0VU on meter = 2.9VPtoP = 2.6dBu) the VU Meters themselves in the VU housing.
Balanced Inputs 1.30 Input channels with balanced audio using RJ45 connectors as illustrated below. Pins 5,7,8 are not connected. The balanced inputs are > 10,000 ohm input impedance and levels are set for +4dBu signals. EIA/TIA 568B WIRING STANDARD COLORS 1,2,3,4,5,6,7,8 Wire Color Audio...
Page 31
Console Logic 1.31 Channel Logic The DB-15 connector on the rear panel of the console has the logic & audio Channel 3,4,5,6,7,8, & 10 feature channel logic for use in talk studios or starting and stop- signals required for supporting a talk studio and controlling the starting & ping source devices.