Beko DEN28320GW Instruction Manual page 42

Table of Contents

Advertisement

are clogged, remove and clean the
impeller. Turn its nut to left to remove
the upper impeller (C, D).
Make sure that the nut is tightened
well when installing the upper
impeller.
Ceiling impeller
Check if the holes on the top ceiling
impeller (3) of your machine are
clogged. If they are clogged, remove
and clean.
3
E
To remove the impeller, slightly
(E) push it upwards and then turn
clockwise (F).
To install the impeller, seat it into its
slot, push slightly upwards and turn
it anticlockwise until it is securely
fitted. When the impeller is released,
check if it rotates without any
obstruction.
39 EN
F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Den28320gb

Table of Contents