Sanyo CE42LH2WP Instruction Manual

Sanyo CE42LH2WP Instruction Manual

42" ip66 rated monitor
Hide thumbs Also See for CE42LH2WP:

Advertisement

Quick Links

INSTRUCTION MANUAL

LCD Monitor

Please read this Instruction book before using your LCD monitor.
We wish you many hours of pleasure from your new LCD monitor.
CE42LH2R
CE42LH2DPB
CE42LH2WP

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo CE42LH2WP

  • Page 1: Instruction Manual

    INSTRUCTION MANUAL LCD Monitor Please read this Instruction book before using your LCD monitor. We wish you many hours of pleasure from your new LCD monitor. CE42LH2R CE42LH2DPB CE42LH2WP...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS ......2 SAFETY PRECAUTIONS ..... . . 3 Installation and Use .
  • Page 3: Safety Precautions

    CAUTION: Please read and retain for your safety. This unit has been designed and manufactured to assure your personal safety, but improper use can result in potential electric shock or fire hazards. In order not to defeat the safeguards incorporated in this monitor observe the following basic rules for its installation, use and servicing .
  • Page 4: Servicing

    This will often require extensive work by a qualified technician to restore the monitor to normal operation. Important recycling information. Your SANYO product is designed and manufactured with high quality materials and components which can be recycled and reused .
  • Page 5: Ac Power Cord Requirement

    . 2. This End-User License is governed by the laws of the State of California . The End-User and Sanyo agree that any action to enforce or inter- pret the terms of this End-User License shall be brought only in the appropriate state or federal court located in Los Angeles County, Califor- nia .
  • Page 6: Installation

    Step: 1 Mains Connection n Connect the display unit to VGA, BNC and Scart con- nector as required. * This figure is CE42LH2WP. 1. Connect the in-line power connector to the Mains Inlet as shown above . 2. Connect the power cord of the LCD monitor to a suitable wall outlet . ✐...
  • Page 7: Remote Control

    The symbol mark and recycling systems described below apply to EU countries and do not apply to countries in other areas of the world . Your SANYO product is designed and manufactured with high quality materials and components which can be recycled and/or reused .
  • Page 8: Controls And Menus

    INSTALLATION Controls and Menus å The LCD display has a Standby light to show there is power. Switching into/from standby mode The Standby mode is used for switching the LCD monitor off for short periods of time . In standby mode the monitor is switched off but is still receiving mains power .
  • Page 9: Menu Operation

    Picture menu n Advanced settings Use the 5 or 6 button to select Advanced settings and press the 1 or 2 button to enter the sub menu as follows . DCDi (Directional Correlational Deinterlacing) is used to process moving angled edge in deinterlacing to get the smoothest and most natural image .
  • Page 10: Pc Adj. Menu

    MENU OPERATION Language is used to select the preferred language . Use the 1 or 2 button to select English, French, German, Italian, Spanish or Dutch . H-Position changes the OSD position horizontally by using the 1 or 2 button . V-Position changes the OSD position vertically by using the 1 or 2 button .
  • Page 11: Installation Mode

    Installation Mode Installation Mode On program Tuner Menu Max Volume Winter mode RC inhibition Child Lock Address Baud rate Panel protection AV Auto shut off Network Standby On Timer Function LED light setting Network initial Temperature Error IP Address Subnet Gateway Select Adjust...
  • Page 12: Operation

    Selection of picture size Select screen size from FULL, FULL ALL, ZOOM 16:9, TITLE IN 16:9, ZOOM 14:9, TITLE IN 14:9, NORMAL or NATURAL WIDE by pressing the WIDE button repeatedly on the Remote Control . ✐ When in AV2 (RGBHV) or PC mode FULL or NORMAL can be selected .
  • Page 13: Pip/Pop Operation

    PIP/POP Operation Using this function, you can enjoy a DVI or Network program and an image (AV1, AV2, AV3 or PC input) at the same time . Press the ON/OFF button on the Remote Control repeatly to select PIP1, PIP2, POP or OFF mode . During the PIP/POP mode, press the Main/Sub Picture Swap but- ton will switch the location for main and sub picture .
  • Page 14: Operation (In Text Mode)

    Teletext Operation Teletext is only available via external sources . Teletext mode can be operated by the following buttons on the Re- mote Control . ✐ Some buttons have dual functions . TXT/TV Press TXT/TV button to select teletext . Press again will display: AV mode: AV/TEXT mode/MIX mode/AV .
  • Page 15: Specifications/Helpful Hints

    SPECIFICATIONS/HELPFUL HINTS Specification Common specification Power source: 100 ~ 240V 50Hz/60Hz Colour system: PAL/NTSC/NTSC4 .43/SECAM AV terminal AV1: Scart CENELEC Standard Input: Composite video, RGB (5V RGB with 5V sync to pin 14) and audio-L/R Output: composite video from AV3 and audio L/R AV2: BNC Input: RGB, H and V/Y, Pb, Pr and audio L/R Output: RGB, H and V/Y, Pb, Pr...
  • Page 16: Dimensions

    n CE42LH2WP 989.0 925.4 1027.0 953.0 930.25 VIEWING AREA(H) DIMENSIONS (WALL MOUNT SCREW) 10 x M6, 1.0 PITCH x 12MM 165.9 126.0 50.8 17.6 402.9 178.5 417.9 ø4.2 (RC RECEIVER) ø4.2 (LED INDICATOR) Unit: mm 418.4 418.4 400.0 200.0 100.0 41.8 Handles x 2 Control buttons...
  • Page 17: Timing List

    PC/DVI-D/COMPONENT SIGNAL SUPPORT TIMING LIST n PC signal support timing Horizontal Vertical Resolution Frequency Frequency (kHz) (Hz) 720 x 400 31 .47 70 .09 640 x 480 31 .43 59 .88 640 x 480 37 .50 75 .00 640 x 480 37 .86 72 .81 640 x 480...
  • Page 18: Rs232C Command Tables

    n Functional Execution Command Table Command POWER ON POWER OFF POWER ON/ OFF (toggle) Wide toggle Input Wide “Natural” direct Wide “Zoom 16:9” direct Wide “Title in 16:9” direct Wide “Zoom 14:9” direct Wide “Title in 14:9” direct Wide “Full” direct Picture Wide “Normal”...
  • Page 19: Rs232C Command Tables

    n Time Read Command Table Status read command Status of accumulated lifetime of panel . CR PANELH (The same as CR_LAMPH Command) Status of accumulated lifetime of monitor . CR MONH (The same as CR_PROJH Command) n Sound control Read Command Table Status read command CR VOLUME Status of volume value .
  • Page 20 SANYO Electric Co., Ltd. N7RAK/ N7RBK/ N7RPK...

This manual is also suitable for:

Ce42lh2rCe42lh2dpbCe42sr4

Table of Contents