Facts 5-9 kW 850 mm 750 mm 375 mm 130 kg Installation by authorised Structural support Nominal effect 7 kW Efficiency technician Check that the wood joists are strong enough Flue gas mass flow 5,9 g/s to bear the weight of the stove and chimney. This manual contains instructions about how The stove and chimney can usually be placed the stoves must be assembled and installed.
Installation distances C310 The minimum distance in front of A = height from floor to chimney the stove opening to combustible connection upwards parts of the building or interior B = height from floor to c/c chimney decoration must be at least 1,4 m. connection rear C = height from floor to air inlet The dimension diagrams only...
Page 5
Efficiency 77,0% Flue gas temperature at nominal output 308°C Flue gas temperature in flue spigot 369°C The undersigned is responsible for the manufacture and conformity with the declared performance. Niklas Gunnarsson, Business area manager NIBE STOVES Markaryd, 1st September 2022...
A sufficient supply of combustion air must always be guaranteed. Air suction systems can interfere with the combustion installation, or maintenance. air supply. The undersigned is responsible for the manufacture and conformity with the declared performance. Niklas Gunnarsson, Business area manager NIBE STOVES Markaryd, January 1, 2022...
Page 7
Montering Vor der Montage Før montering Om kaminen behöver läggas ned för att Wenn der Kaminofen in liegender Hvis ovnen må legges ned for å flyttes, förflyttas bör lösa delar demonteras. Position versetzt werden muss, sind lose bør løse deler demonteres. Demontering Demontering av eldstadsbeklädnad beskrivs Komponenten zu demontieren.
Page 8
Bakåtanslutning till murad skorsten Rückseitiger Anschluss an einen gemauerten Schornstein Bakmontering til murt skorstein Raccordement par l’arrière à une cheminée de maçonnerie Rear connection to a masonry chimney Tilslutning bagud til muret skorsten Liitäntä taaksepäin muurattuun savupiippuun Collegamento alla canna fumaria in muratura dal retro della stufa Achterwaartse aansluiting op een gemetselde schoorsteen Ø...
Page 9
Toppanslutning till skorsten Varmluftsgallret måste vara monterat innan skorstenen toppansluts. Oberseitiger Anschluss an den Schornstein Das Warmluftgitter muss montiert sein, bevor ein Schornsteinanschluss an der Oberseite erfolgt. Toppmontering til skorstein Varmluftsgitteret må være montert før skorsteinen topptilkobles. Raccordement par le haut Monter la grille d’air chaud avant le raccordement à...
Page 12
Uppställning av luckan Spærring af lågen Luckan kan spärras i öppet läge, med hjälp av tryckknappen på Lågen kan spærres i åben position ved hjælp af trykknappen kaminens undersida. under brændeovnen. Aufstellung der Tür Luukun asennus Mithilfe der Taste an der Kaminofenunterseite kann die Tür in ihrer Luukku voidaan lukita avattuun asentoon takan alapuolella olevalla painonapilla.
Demontera eldstadsbeklädnaden (Vermiculit) So demontieren Sie die Brennraumauskleidung (Vermiculit) Slik demonterer du ildstedsbekledningen (Vermikulitt) Voici comment démonter l’habillage du foyer (Vermiculite) How to remove the hearth surround (Vermiculite) Sådan afmonterer du ovnbeklædningen (Vermiculite) Näin irrotat tulipesän verhouksen (vermikuliitti) Come smontare il rivestimento del focolare (vermiculite) Zo demonteert u de kachelbekleding (vermiculiet) Handle with care!
Page 15
For installation in the UK and in smoke control areas Mandatory for smoke control areas Contura 310, 320 and 330, 7 kW woodburning stoves has been The permanent stop must be installed if the appliance is to be recommended as suitable for use in smoke control areas. This used in a smoke control area, this stop must not be removed in when burning wood logs and operated in accordance with these smoke control areas, otherwise an offence will be committed if...
Page 16
811303 IAV SE-EX C310-4 NIBE AB · Box 134 · 285 23 Markaryd · Sweden 2023-10-18 contura.eu...