Adjustment Procedure Start Up; How To Get Into Adjustment Mode; Changing Data And Selecting Adjustment Code; Memory Initialize - Hitachi P50H401/DW3-U Service Manual

Hide thumbs Also See for P50H401/DW3-U:
Table of Contents

Advertisement

1 ADJUSTMENT PROCEDURE START-UP
The P50H401, P50T501 and the P50H4011 PDP TV sets
pass through adjustment procedures during the assembly
process. These adjustments must be done to assure the
best performance of the PDP set for the consumer.
Also, after servicing, these same adjustments must be
done. The adjustments are all made through the I
by changing data in the Adjustment mode menu.
1.1 HOW TO GET TO ADJUSTMENT MODE
Chassis adjustment mode can be access by pressing
the R/C keys MENU + MENU + 8 + SELECT to enter
adjustment mode. For some parameters the only way
to see them is by selecting the parameter number than
press SELECT in order to see it; then DATA can be
change if other parameter needs to change then press
key then repeat the same procedure.
ADJUST MODE
FACT RESET
MEMORY INIT
RGB
WHITE BAL HIGH
WHITE BAL MED
WHITE BAL STD
WHITE BAL B/W
To escape from Adjustment Mode press "INPUT"
key on Front panel or EXIT key of R/C to exit
service adjustment mode.
1.2 CHANGING DATA AND SELECTING ADJUSTMENT
CODE
When the PDP set is in adjustment mode, the cursor
,
and MENU keys of the remote control or front panel
may be used as the adjustment keys.
(1) Use any Hitachi remote control when making an
adjustment.
,
keys are used for selecting adjustment item.
,
keys are used for changing data values.
MENU key is used to advance through the adjustment
mode menus and pages.
Part of H model's remote control
BACK TO ADJUSTMENTS
C bus
2
(2) To make a selection, use the NUMBER pad on the PDP
R/C ; example : select DEVICE press 69 then SELECT
the DATA shown is "EB" ; if this DATA needs to be change
press the
key to store the new DATA value.
normal condition.
(3) After finishing the necessary adjustment press the R/C
EXIT key or EXIT key on the front panel.
Adjustment mode is released and PDP set returns to
normal condition.
,
,

2 MEMORY INITIALIZE

2.1 MEMORY INITIALIZE OPERATION

The execution of this function returns the
NOTE:
adjustment codes to the preset values, therefore,
adjustment data will be lost.
Procedure
(1) Enter Adjustment mode by the method described in
sub-items 1.1 and 1.2 from item 1 ("Adjustment
procedure start up").
(2) Get to the second page of Adjust Mode by pressing
remote control "Menu" key once, or with either the
R/C or front panel
(3) Select MEMORY INIT adjust code.
(4) Activate MEMORY INIT by pressing
more than 3 seconds.
(5) Check the following process for initialization opera-
tion.
43
Part of T model's remote control
Front Panel control buttons.
,
,
keys to modify, when finish press SELECT
cursor keys several times.
,
DW3U
cursor key for