Summary of Contents for emmeti Merriott PPED Series
Page 1
Installation, operating & instruction manual Electric Range (Digital Control E-D) Panel Radiators Class I - 230V - 50Hz PLEASE LEAVE THIS MANUAL WITH THE END USER...
Contents Product Information Safety Information Waste Disposal According to The WEEE Directive (2012/19/EU) General Information Installation Operation 6.1 General 6.2 Heating 6.3 Advanced Mode 6.4 Stand-alone Radiator 6.5 Radiator Connected to a Central Control 6.6 Radiator Connected to a Unisenza Plus Gateway 6.7 Radiator Connected to a Touch4 Programmer Parameter Menu Maintenance, Repair &...
Electric Range (Digital Control E-D) Product Information Min. 100mm Min. 200mm Min. 100mm Min. 100mm Min. 100mm Safety Clip-on Brackets OUTSIDE ZONES Zone 1 Zone 2 Zone 2 Zone 0 Step 1 Step 2...
Page 4
Electric Range (Digital Control E-D) Product Information (cont...) Height Length 1000 1250 1300 1600 2000 (mm) (mm) 1016 1320 1727 Cable Hook Assembly...
Page 5
Electric Range (Digital Control E-D) Product Information (cont...) Stand-alone Operation Switched Fused Spur Terminal Block Wire Colours BR = Brown BK = Black (Neutral) BL = Blue G/Y = Green/Yellow Connected to a Touch4 Programmer Wire Colours BR = Brown PILOT WIRE FROM PROGRAMMER BK = Black (switched live)
Page 6
Electric Range (Digital Control E-D) Product Information (cont...) Wire Colours Touch BR = Brown BK = Black BL = Blue G/Y = Green/Yellow Other products in Zone Other products in Zone Zone Zone Other products in Zone Other products in Zone Zone Zone...
Page 7
Electric Range (Digital Control E-D) Product Information (cont...)
Page 8
Electric Range (Digital Control E-D) Product Information (cont...)
Electric Range (Digital Control E-D) Safety Information Due to the safety standard and its cord out of reach of children EN 60335, the text below is aged less than 8 years. Children obligatory for all electric products, of less than 3 years should be not only radiators.
Electric Range (Digital Control E-D) General Information Connection > The electrical installation must comply with local or national regulations. > This appliance is a sealed electric radiator designed for > The radiator should be connected by a suitable and fixed wall-mounted installation. qualified electrician.
Electric Range (Digital Control E-D) 6. “Room temperature” indicator. How to View the Measured Room Temperature 7. Operating mode menu. 8. "Open Window" function indicator. 9. Master/Follower indicator (with Unisenza PLUS Gateway). 10. Warning indicator. 11. Installation parameter indicator. 12. Parameters number when icon “11” is displayed. 13.
11. When you return to the main screen, the selected programme and Emmeti Electric radiators can be connected to a programmable time settings will now be displayed. system by either a Unisenza PLUS Gateway and Unisenza Plus To select a heating programme, please refer to section 7.0, and select...
Electric Range (Digital Control E-D) All: Expert Setting NOTE: When connected to the Unisenza PLUS Gateway, the product can only be locked and unlocked in the App to set – Press “ ” to enter this parameter. Select with “ ”...
Page 14
Electric Range (Digital Control E-D) SLA or FOLL: (Not Used) NOTE: When considering the permanent use of the radiator at ~60°C or ~75°C maximum, the following correction factor should Factory set to “ ” and must not be altered. be applied for the output. NOTE: If connected to a Unisenza PLUS Gateway, this setting will only be available in the App.
Page 15
Electric Range (Digital Control E-D) Defining a User Programme NOTE: Once saved, the user defined programmes are not lost in the event of a power cut. However, the time will reset to 00:00 and day 1 when the power returns, if not set, so the product may not heat at the expected times.
Page 16
Electric Range (Digital Control E-D) > > SAVE Press the “ ” key to confirm the time at which the mode will When all of the days have been defined, the word “ ” change over from Comfort to Reduced. The symbol will will be displayed.
Electric Range (Digital Control E-D) Maintenance, Repair Technical 10.0 and Disposal Characteristics WARNING: Disconnect electrical supply before carrying out Environmental: any maintenance activity. - Operating temperature -30°C to +50°C > The product should be cleaned using a soft damp cloth. - Storage temperature -30°C to +70°C Do NOT use chemical or abrasive cleaners as they will damage...
Electric Range (Digital Control E-D) Eco Directive Characteristics 11.0 Model identifier(s): PPEDxxxxxxx / FAEDxxxxxxx / FGEDxxxxxxx - where “x” may be any character. Item Symbol Value Unit Item Unit Type of heat input, for electric storage Heat output local space heaters only Nominal heat output where “xxxxxx”...
Page 20
Merriott UK & Ireland Purmo Group (UK) Ltd, Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG Tel: 0330 0415 472 sales@merriottuk.com sales@merriott.ie www.merriottuk.com / www.merriott.ie Follow us on @MerriottUK and...