REPLACE BATTERY; Fig. 11, 11a
C
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in
back of FLUSH VALVE COVER (3). Fig. 11.
2. Rotate COVER (3) to the right and pull off. Fig. 11.
3. Turn COVER (3) over and disconnect the SENSOR (4)
from the BATTERY HOLDER (5). Remove the BATTERY
CONTAINER (6) with BATTERY HOLDER (5) and
BATTERY (7) inside. Fig. 11a.
4. Remove BATTERY HOLDER (5) from BATTERY
CONTAINER (6). Fig. 11a.
5. Remove old BATTERY from BATTERY HOLDER (5).
Install the new BATTERY (7) making sure the shape
of the BATTERY follows the shape of the BATTERY
HOLDER (5). Fig. 11a.
6. Insert BATTERY HOLDER (5) with BATTERY into
BATTERY CONTAINER (6). Insert BATTERY
CONTAINER (6) into flush valve COVER (3). Fig. 11a.
7. Connect BATTERY HOLDER (5) to SENSOR (4) and
reverse the above steps to assemble flush valve. Fig. 11a.
REPLACE LONG LIFE POWER
D
PACK; Fig. 11, 11b
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in
back of FLUSH VALVE COVER (3). Fig. 11.
2. Rotate COVER (3) to the right and pull off. Fig. 11.
3. Turn COVER (3) over and disconnect SENSOR (4) from
LONG LIFE POWER PACK (8). Fig. 11b.
4. Remove old LONG LIFE POWER PACK (8) and insert
new unit. Fig. 11b.
5. Connect new LONG LIFE POWER PACK (8) to SENSOR
(4). Reverse the above steps to assemble flush valve.
Fig. 11b.
Fig. 11
1
2
Fig. 11a
STANDARD BATTERY
3
6
5
Fig. 11b
LONG LIFE POWER PACK
3
8
7
REMOVE OLD
INSTALL
BATTERY
NEW
BATTERY
- P 2
C R
- P 2
C R
7
REMOVE
BATTERY
HOLDER
6
4
REMOVE OLD
LONG LIFE
POWER PACK
INSTALL NEW
LONG LIFE
4
POWER PACK
M965647 REV. 1.4 (7/15)
3
5
5
8