Alfa Electric AVE145 User Manual

Air conditioner for electrical enclosure outdoor application

Advertisement

Quick Links

USER'S MANUAL (PART 2)
AIR CONDITIONER FOR ELECTRICAL ENCLOSURE
Division of:
ALFAPLASTIC s.a.s.
Via Della Valle, 39 – 20841 Carate Brianza (MB) Italy
Tel. +39 (0362) 903.539 Fax. +39 (0362) 975.133
Mail:
info@alfaelectric.com
www.alfaelectric.com
Document: UMA-CDZ-AVE145-01
Description
Original user's manual for air conditioner AVE145 series
Language: English
Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE
UMA-CDZ-AVE145-01
OUTDOOR APPLICATION
AVE145
Date
ISSUE
07/01/2019
REV. 01
04/08/2021
REV. 02
REV. 03
Name
Ascheri M.
Ascheri M.
Page 1/23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVE145 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alfa Electric AVE145

  • Page 1 Mail: info@alfaelectric.com www.alfaelectric.com Document: UMA-CDZ-AVE145-01 Date Name Description ISSUE 07/01/2019 Ascheri M. REV. 01 04/08/2021 Ascheri M. Original user’s manual for air conditioner AVE145 series Language: English REV. 02 REV. 03 Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 1/23 UMA-CDZ-AVE145-01...
  • Page 2 Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 2/23 UMA-CDZ-AVE145-01...
  • Page 3: Table Of Contents

    DIGITAL THERMOSTAT ....................15 MECHANICAL THERMOSTAT ..................18 5 – SPARE PARTS LIST ....................... 19 5.1- SPARE PARTS FOR AVE145.000, AVE145.010, AVE145.020 ..........19 5.2- SPARE PARTS FOR AVE145.001, AVE145.011, AVE145.021 ..........19 6 - ACCESSORIES ........................20 FLOW DIVERTER ......................20 6.1.1...
  • Page 4: Technical Data

    1 - TECHNICAL DATA CONTROL TYPE ARTICLE CODE Mechanical thermostat AVE145.000 AVE145.010 AVE145.020 Digital thermostat AVE145.001 AVE145.011 AVE145.021 FEATURES Unit Power supply V | ph| Hz 230 | 1 | 50/60 115 | 1 | 50/60 400 | 2 | 50/60...
  • Page 5: Installation

    AIR CONDITIONER AVC series must be handled in upright position and protected against accidental tipping over. Air conditioners AVE145 series are fitted with female blind threaded insert to screw male lifting eye bolts. The air conditioner handling, when unpacked, can be done thanks to lifting eye bolt.
  • Page 6: Fitting

    2.3 FITTING 1) Make the fixing hole on the enclosure as is shown in the drilling template Deburr all sharp edges to avoid accidental injuries Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 6/23 UMA-CDZ-AVE145-01...
  • Page 7 The enclosure must be IP 54 protected, if enclosure is not airtight, condensate production could increase. The enclosure IP54 degree is guaranteed only if the air conditioner is proper mounted. Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 7/23 UMA-CDZ-AVE145-01...
  • Page 8: Electrical Connection

    Upstream of the electrical connection, an efficient disconnection system must be provided and it must be clearly identified Air conditioner is already fitted with a temperature controller, no additional temperature control must be connected upstream of the unit. Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 8/23 UMA-CDZ-AVE145-01...
  • Page 9: Wiring Diagram

    3.1 WIRING DIAGRAM 3.1.1 AVE145.000 Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 9/23 UMA-CDZ-AVE145-01...
  • Page 10: Ave145.010

    3.1.2 AVE145.010 Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 10/23 UMA-CDZ-AVE145-01...
  • Page 11: Ave145.020

    3.1.3 AVE145.020 Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 11/23 UMA-CDZ-AVE145-01...
  • Page 12: Ave145.001

    3.1.4 AVE145.001 Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 12/23 UMA-CDZ-AVE145-01...
  • Page 13: Ave145.011

    3.1.5 AVE145.011 Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 13/23 UMA-CDZ-AVE145-01...
  • Page 14: Ave145.021

    3.1.6 AVE145.021 Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 14/23 UMA-CDZ-AVE145-01...
  • Page 15: Starting And Adjustment

    4.1 DIGITAL THERMOSTAT (only for AVE145.001, AVE145.011, AVE145.021) Compressor turns ON when internal enclosure temperature rises up to set point value + temperature differential (parameter C1) and the minimum interval of two successive switch-on of the compressor (parameter C2) is elapsed.
  • Page 16 For example, St is set to 0℃, and it will automatically adjust to 32℉ after switch; C4 (calibration value of cabinet sensor) is set to +8℃,and it will automatically adjust to +20*(8/10)=+16℉. Suggestion: Switch Celsius/Fahrenheit first, then adjust the value of related parameter items to ensure correct parameter configuration. Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 16/23 UMA-CDZ-AVE145-01...
  • Page 17 Refrigeration stops when the cabinet temperature < temperature set-point In case of cabinet sensor fault, When =0, compressor start and stop time in the mode of “run/stop in a proportional time” is disabled, refrigeration stops. Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 17/23 UMA-CDZ-AVE145-01...
  • Page 18: Mechanical Thermostat

    <A5 and alarm delay time run out, controller will display rL 4.2 MECHANICAL THERMOSTAT (only for AVE145.000, AVE145.010, AVE145.020) Compressor turns ON when internal enclosure temperature rises up to set point value of thermostat.. Condenser fan turns ON when refrigerant pressure rises up to pressure switch set Compressor and condenser fan turn OFF when internal enclosure temperature decreases below set point value –...
  • Page 19: Spare Parts List

    5 – SPARE PARTS LIST 5.1- SPARE PARTS FOR AVE145.000, AVE145.010, AVE145.020 REFERRED TO WIRING DESCRIPTION CODE DIAGRAM Evaporator fan VCENT190D230V Compressor BSD122DT-P6AU Condenser fan VCENT220D230V Evaporator fan capacitor CON2UFS2M8F Compressor capacitor CON20UFS2M8F Condenser fan capacitor CON2UFS2M8F Regulating thermostat TERMOSTTR2...
  • Page 20: Accessories

    6.1.1 Flow diverter installation The flow diverter allows to deflect the fresh air towards the bottom of the enclosure allowing for better cooling Fix the Flow diverter with included n°2 screws. Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 20/23 UMA-CDZ-AVE145-01...
  • Page 21: Warranty

    WARRANTY Alfa Electric Division of: ALFA PLASTIC s.a.s. Via Della Valle, 39 – 20048 CARATE BRIANZA (MI) Tel. +39 (0362) 903.539 – Fax +39 (0362) 975.133 Mail: info@alfaelectric.com www.alfaelectric.com guarantees that the product is free from any quality defects. The product is guaranteed for a period of 12 months from the date of delivery, provided it operates under the following conditions: 1.
  • Page 22: Ue Declaration Of Conformity

    UE DECLARATION OF CONFORMITY Alfa Electric Division of: ALFA PLASTIC s.a.s. Via Della Valle, 39 – 20841 CARATE BRIANZA (MB) Tel. +39 (0362) 903.539 – Fax +39 (0362) 975.133 Mail: info@alfaelectric.com www.alfaelectric.com DECLARE THAT THE AIR CONDITIONER FOR ELECTRICAL CABINETS...
  • Page 23 NOTES Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 23/23 UMA-CDZ-AVE145-01...