Panasonic FY-E15DZ1 Operation Instruction Manual
Panasonic FY-E15DZ1 Operation Instruction Manual

Panasonic FY-E15DZ1 Operation Instruction Manual

Energy recovery ventilator

Advertisement

Quick Links

Model No.
FY-E15DZ1
FY-E15DZ1L
Accessories:
Model label...............................1 piece
Operation Instruction....................1 books
(Please be sure to give them to customer)
Thanks for purchasing Panasonic Energy Recovery Ventilator .
Please read this instruction carefully to understand how to use this product correctly before
installation and construction, especially
sure to use safely. After you've read it, keep it well so that you can easily find it if necessary.
Please be sure to give this instruction to end user.
(Containing the Installation Instruction)
FY-E25DZ1
FY-E25DZ1L
Operation Instruction
Energy Recovery Ventilator
FY-E35DZ1
FY-E35DZ1L
CONTENTS:
SAFETY PRECAUTIONS...................2~4
FEATURES.............................................5
USING CAUTIONS.................................5
OPERATION...........................................6
MAINTENANCE METHODS...............7~8
SAFETY PRECAUTIONS..................9~10
INSTALLATION CAUTIONS..................11
METHODS......................................16~19
TRIAL OPERATION...............................19
SPECIFICATION.................... Back cover
safety precautions (page 2~4)、(page 8~9)make
FY-E50DZ1
FY-E50DZ1L

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic FY-E15DZ1

  • Page 1: Table Of Contents

    Operation Instruction……..….1 books SPECIFICATION....Back cover (Please be sure to give them to customer) Thanks for purchasing Panasonic Energy Recovery Ventilator . Please read this instruction carefully to understand how to use this product correctly before installation and construction, especially safety precautions (page 2~4)、(page 8~9)make...
  • Page 2: Operation Instruction Safety Precautions

    SAFETY PRECAUTIONS <must be complied> In order to prevent the damage to using personnel and other personnel and avoid the loss of property, please be sure to comply with the following cautions. The following marks are used to distinguish the damage from damage degree caused by ignoring the mark or operating by wrong methods.
  • Page 3 If the power supply cord appears worn, If the appliance is not used for a long in order to avoid the danger, changing time, in order to prevent it from work need to be done by authorized dropping, it should be removed. personnel.
  • Page 4 SAFETY PRECAUTIONS <must be complied> Don’t use it in the following locations. Locations exposed to high Locations with large amounts Locations with high humidity. temperature or direct flame. of cooking fumes. Do not install in high humidity Avoid installing the ERV in locations locations such as bathrooms.
  • Page 5: Model Label

    FEATURES 1. Energy saving ventilation Thanks to efficient recovery of the thermal energy lost during ventilation (fresh air load), you can save an air-conditioning fee. 2. Facility saving Thanks to a greatly reduction of fresh air load, part of the thermal energy is recovered so that the air-conditioning can become mini-type properly.
  • Page 6: Handling Methods On Abnormal Operation

    PART NAME AND USING METHODS (model label adhesive location). Using methods: Please use the switch installed Caution on the wall (separately sold). Please use the mode heat exchange When stopping. In winter, please use the mode heat exchange . In winter, when the room is heated and operation in the mode normal ventilation ,condensation produced on the surface of the unit, which will make the ceiling dirty or cause high...
  • Page 7: Maintenance Methods

    MAINTENANCE METHODS Maintenance methods for main unit █  If using the ERV for a long time, filter will be clogged by dirt and dust which reduces the air volume and ventilation effect, get the noise louder .Please do the routine cleaning as per the dirty degree. Rough using condition(large amount of dust location) will cause the reduction of air volume and filter efficiency, to keep the unit perform well, please raise the times of cleaning or replacing the filter properly.
  • Page 8 MAINTENANCE METHODS Down maintenance for filter █  (*when setting the down maintenance cover,meanwhile you must reserve the side maintenance cover in advance.) 1. Cleaning methods for Indoor filter 1) Remove the two screws fixed in the indoor filter and the indoor down maintenance cover toward the arrow A.
  • Page 9: Installation Instruction:

    SAFETY PRECAUTIONS <must be complied> In order to prevent the damage to using personnel and other personnel and avoid the loss of property, please be sure to comply with the following precautions. The following marks are used to distinguish the damage from damage degree caused by ignoring the mark or operating by wrong methods.
  • Page 10 CAUTION Please don’t set the indoor air inlet in It must use the part during specified location with high temperature or high the installation (include the humidity. accessories) It may cause the damage inside the unit, It may cause the unit dropping, fire Prohibition which can result in abnormal operation, and electric shock If not using the...
  • Page 11: Installation Cautions

    INSTALLATION PRECAUTIONS <must be complied> CAUTION Please avoid the following duct installation. (1) excessive bending (2) multi-times bending (3) reduction the diameter of connecting duct Prohibition Prohibition Prohibition It may cause the unexpected accident. Don’t install the unit in locations such as Do not install in high humidity locations machinery, chemical and research plant such as bathrooms.
  • Page 12: Part Name And Dimensions

    UNIT: mm 1. Do routine cleaning to heat exchange core and filter, maintenance cover must be set. FY-E15DZ1 2. It’s allowed to only set the side maintenance cover. 3. Please reserve the side maintenance cover in advance if setting the down maintenance cover.
  • Page 13 PART NAME AND DIMENSIONS Cautions for maintenance cover UNIT: mm 1. Do routine cleaning to heat exchange core and filter, maintenance cover must be set. FY-E35DZ1 2. It’s allowed to only set the side maintenance cover. 3. Please reserve the side maintenance cover in advance if setting the down maintenance cover. * it won’t conduct the maintenance without the side maintenance cover.
  • Page 14 PART NAME AND DIMENSIONS Cautions for maintenance cover UNIT: mm 1. Do routine cleaning to heat exchange core and filter, maintenance cover must be set. FY-E15DZ1L 2. It’s allowed to only set the side maintenance cover. 3. Please reserve the side maintenance cover in advance if setting the down maintenance cover. * it won’t conduct the maintenance without the side maintenance cover.
  • Page 15 PART NAME AND DIMENSIONS Cautions for maintenance cover UNIT: mm 1. Do routine cleaning to heat exchange core and filter, maintenance cover must be set. FY-E35DZ1L 2. It’s allowed to only set the side maintenance cover. 3. Please reserve the side maintenance cover in advance if setting the down maintenance cover. * it won’t conduct the maintenance without the side maintenance cover.
  • Page 16: Methods

    Install 4 ceiling suspension bolts(separately buy:M10) Please align the suspension angle of main unit with ceiling suspension bolts. FY-E15DZ1 FY-E15DZ1L FY-E25DZ1 FY-E25DZ1L dimension of suspension point dimension of suspension point dimension of suspension point...
  • Page 17 Please adjust the length of ceiling suspension bolt Seal the junction of an adaptor and a duct by to ensure the distance between the downside of unit adhesive tape or seal tape (separately buy) to and ceiling is over 25mm, the distance between the prevent any air leakage.
  • Page 18 Connection with power(Connection before ceiling construction) Wire connection diagram wirig diagrams of lefe tyfe and right type are symmetrical. Precaution during the wire connection: The dashed line as shown in the figure must be conducted on spot by construction personnel. Please use the switch, its contact point sepate distance is above 3mm.
  • Page 19: Trial Operation

    Under the situation of Aircon operation Failure Available operation Button ① Button ② Button ③ With Aircon high — Normal Button ① Button ② Button ③ Heat Without Aircon ventilation exchange Remove the cover of switch box. Model label Remove the three screws fixed in the cover of switch box. The power supply cord goes through the wire plug, as required in figure, fix the wire connecting power supply cord and switch in the terminal block,and fix the ground wire in the...
  • Page 20: Specification

    Model Notch air volume (dB(A)) (m³/h) (Pa) Cooling Heating Cooling Heating FY-E15DZ1 FY-E15DZ1L FY-E25DZ1 FY-E25DZ1L FY-E35DZ1 FY-E35DZ1L FY-E50DZ1 FY-E50DZ1L Explanation: The values shown as instruction are measured in the condition of total pressure when ERV operates. The input power indicated in name plate is the maximum value at the static pressure of 0 Pa.