03. DISABLE DIRECT HAZARDS / SAFETY REGULATION

Disconnection of high
voltage
Automatic disconnection
If a serious accident has occurred that has either
triggered an airbag to deploy or the seatbelt pre-
tensioner to activate, the traction battery pack is
automatically disconnected from the rest of the
high voltage system.
Make sure the traction battery is disconnected
before starting any rescue procedures. Please see
the section
"High voltage Manual service discon-
nect" in this chapter.
WARNING
Residual voltage can remain in the system
outside the traction battery for approximately
10 seconds after the accident.
Secure that the vehicle is stabilized
and turned off
When possible, always make sure that
the vehicle is turned off and stabilized.
See chapter
STABILISATION/LIFTING
information.
02. IMMOBILISATION/
for more
Disconnection of the 12 V battery
!
IMPORTANT
If the power front seats need to be adjusted,
this must be done before the 12 V battery
is disconnected, please see the section
"Adjusting the seats and steering
chapter
04. ACCESS TO THE
1. Open the hood.
2. Identify the 12 V battery.
15
wheel" in
OCCUPANTS.