Table of Contents
loading

Summary of Contents for Next ATS 16

  • Page 1 User Guide                                 Automatic Transfer Switch (ATS 16)                       www.nextups.eu    ...
  • Page 2: Table Of Contents

    Table of Contents 1.   Introduction ..............2   2.   Product Overview ............2   3.   Important Safety Warnings ........... 3   4.   Operation Indicators & Status ........3   5.   Installation ..............5   6.   Operation ..............6   7.  ...
  • Page 3: Introduction

    Introduction This ATS 16 product is designed with two independent power inlets to supply power to the load from a primary power source. Should primary power source fail, the secondary will automatically back up the connected equipment without any interruption. The transfer time from one line to another is seamless to the connected equipment.
  • Page 4: Important Safety Warnings

    The power supply socket must be easily accessible to the operator. WARNING!! The ATS 16 has been designed exclusively to operate indoors. It is advisable to install it in areas where no inflammable liquids or gases, or other harmful or noxious substances, have been stored.
  • Page 5       Indication Condition Alarm type description status       Source A (2)   Source A is priority Priority Source B (2) setting     Source A (2) LEDs Source B is priority Source B (2)   Inlet A has no power input  ...
  • Page 6: Installation

      Connecting the Unit For connecting the ATS 16, plug “input source A connector” and “input source B connector” to the two independent power sources or UPSs depending using the SCHUCKO-IEC or IEC-IEC 16A cables supplied. Plug the user load to the output 10A (“Output 1 and 2”) or 16A (“Output 3”) sockets depending on user’s requirements.
  • Page 7: Operation

      Communication Port The ATS 16 is supplied with the following communication ports: Serial port is available with RS232 com. port and USB com. port on the front l panel. NOTE: the use of one port automatically excludes the other.
  • Page 8 The contacts port is formed using six (6) pins numbered from left to right (see fig. 1), which can be connected to an external monitoring system (such as a BMS) in order to monitor the operational status of the ATS 16. The external equipment must respect the voltage and current characteristics of contacts port.
  • Page 9: Trouble Shooting

    Shut down the ATS 16 completely and The display shows There is power wait for a few seconds. nothing or provides supply problem in Switch the ATS 16 on again, if the incorrect display. problem persists, contact the nearest information. technical support centre.
  • Page 10: Specifications

        NEXT UPS Systems Part number 88009 www.nextups.eu                                                                                 9  ...
  • Page 11: 10. Appendix

    Source B.     When input voltage of Source A is     back to normal, the ATS 16 will Return voltage point Low point: 190V switch back to Source A. (Setting for Source A High point: 248V...