AMERICAN ACCESS SYSTEMS ADVANTAGE DKW 300MHz Wireless Keypad INSTALLATION AND PROGRAMMING INSTRUCTIONS MODEL 19-100W PLEASE READ BEFORE USING THIS EQUIPMENT Technical Support: 303-799-9757 Monday thru Friday 8:00 a.m. to 4:30 P.M MST...
Page 2
What we will do: If your AAS product is defective and returned within 2 years of the date of purchase, we will repair it or, at our option, replace it at no charge to you. If we repair your AAS product, we may use new or reconditioned parts. If we choose to replace your AAS product, we may replace it with a new or reconditioned one of the same or similar design.
PARTS CHECKLIST Enclosed with this box you should have the following items. Description Control Station 1/4 by 1/2 carriage bolts (Post mount units only) 1/4-20 hex nuts (Post mount units only) If any of the above items are missing from this box, contact American Access Systems TOOLS YOU WILL NEED Wire nuts or appropriate connectors Wire strippers...
7/16" socket. Mounting the unit to an AAS gooseneck (18-001) or double height (18-003)pedestal Locate the four carriage bolts and four hex nuts found inside the unit box. Place the unit up to the pedestal flange and insert the four carriage bolts from the backside.
Page 5
THE MASTER CODE AND ACCESS CODES Depending on which model you have, your unit may be programmed with 50 multiple (4 digit) ACCESS CODES, The MASTER CODE is a 4 digit programmable code used for accessing the program mode. Note: The model number of the unit is located on the inside face of the unit.
Page 6
PROGRAMMING A person desiring a access to the program mode will enter the present MASTER CODE. If the master code is valid a GOODBEEP will be heard prompting the person to enter a number corresponding to the SUB-MODE, eg. (MASTER CODE) then (Number corrresponding to Sub-Mode). Once in the program mode the individual will have approximately 15 seconds between keypresses or the unit will sound an ERRORBEEP and exit the program mode.
Page 7
“4” Sub-Mode 4 (Set Relay Output Time from 1/2 to 9 secondsTo set the relay output time in seconds enter the PRESENT MASTER CODE, followed by 4, and then the relay output time in seconds. NOTE: “0” = 1/2 seconds. (PRESENT MASTER CODE) then 4 then (RELAY OUTPUT TIME) Should you make an entry error, simply press the * key and re-enter the correct data.
Troubleshooting Solution Problem When I enter 1251 on the keypad the gate will 1251 is the Master Code or programming access not open. code. It will not open the gate unless the unit is in sleep mode. Program a gate access code into the unit using Sub-Mode 1 (listed in the programming instructions).