Charnwood OLX Oil Fired Hearth Boiler Operating Instructions GENERAL POINTS Before using the boiler for the first time, check with the installer that it has been correctly installed and commissioned. Do not attempt to use the boiler before it has been commissioned.
Page 5
Replace the fibreglass coal effect, with the rear edge passing just under the Perspex. Re-fit the front fence and replace the coals. 1) Lift Bulb from clip Sleeve Bulb 2) Remove Bulb from Holder Fig. 3. Flame Effect Bulb Replacement Page 5 OLX V5.2 05.04...
Charnwood OLX Oil Fired Hearth Boiler Installation Instructions HEALTH AND SAFETY PRECAUTIONS boiler and a ducted air supply must be provided to the Please take care when installing the appliance that the right hand side of the boiler at this point. A two metre...
In order to ensure quietness of operation of the The boiler waterways totally enclose the combustion Charnwood OLX a single pipe system is used. The oil chamber. This means that the maximum temperature storage tank should ideally be positioned with the base below the boiler is 100°C and therefore a...
Bleed Screw Oil Pressure Adjustment screw. COMBUSTION CHAMBER ASSEMBLY Clockwise to Increase, Bleed Hose Anti-Clockwise to Decrease. Connection Point The boiler comes with the internal insulation bricks and Fig. 9. Oil Pump Details Page 10 OLX V5.2 05.04...
Once the installation is complete ensure that the air Fig 11. Combustion Chamber Components control is set at maximum (No. 10) before the burner is fired (see Fig. 8.) Otherwise sooting may occur. This will be re-adjusted during commissioning. Page 11 OLX V5.2 05.04...
Flue Fixings Boiler tappings are 1” BSP Female, 2 each side ø130 (693 with optional fan heater) Charnwood OLX Overall Dimensions (all dimensions are in mm) Page 12 OLX V5.2 05.04...
Page 13
Advise the customer on the use of the boiler, and the system controls. Also advise of the need for annual servicing of the boiler by an OFTEC trained & registered technician. Leave these Operating and Installation Instructions with the customer. Page 13 OLX V5.2 05.04...
OLX Boiler - Specifications Max. Allowable Operating Temperature 95°C Max. Allowable Operating Pressure 3 bar (Pressure Class 2) Test Pressure 4.5 bar Heat Output Range 11-13 kW Heat Input at Rated Output 15 kW Oil Pump Pressure 110 - 140 psi Required Flue Draught 0.07 in H O (0.17 mbar)
Issue C Charnwood OLX Mk.2 Parts List NOTE! Mk.3 Replacement Burners for appliances before Serial No. 45****1562 require bracket to align control box with re-set hole. 45 44 47a 47b 47c Item Part No. Description Item Part No. Description 008/KV35S Door Seal Set Inc.