Typical Field Wiring Connection
For Each Device
Wire Connectors
Provide suitable
strain relief.
Supply from
Branch
Circuit Box
4. Make the Electrical Connections – Canada
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the pump motor, in-line heater (if included), and
blower to a properly grounded, grounding-type Ground-Fault Circuit-Interrupter (GFCI) or
Residual Current Device (RCD). This will provide additional protection against line-to-ground
shock hazard.
NOTE: A label identifying the model number and electrical rating of the whirlpool is located near the
whirlpool pump.
Locate and secure each supplied junction box a minimum of 1-1/2" (38 mm) above the subfloor.
The whirlpool controls and system have been prewired at the factory. A qualified electrician should
make a routine service connection to the junction box.
Connect service to the junction box. The 60 Hz model junction box contains line (black) and neutral
(white) wires and a ground lug.
A 120 V, 15 A dedicated circuit is required for each device. Provide a Class A GFCI or RCD for each
dedicated circuit.
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor must not be connected to any current-carrying conductor.
Bond in accordance with national and local codes.
1208027-2-F
Bond in accordance with
applicable codes.
Ground
Line (Black)
Neutral (White)
Blower
8
Heater
Pump
Junction Box
Junction
Box
Junction
Box
Kohler Co.