Download Print this page

Penman Collection VEGA 100 Installation And Operating Instructions Manual

Multi fuel stoves

Advertisement

Quick Links

VEGA 100 - VEGA 200 - VEGA 200SL
MULTI FUEL STOVES
APPROVED - CONFORMING TO EN13240:2001 and
EN13240 A2:2004
INSTALLATION AND OPERATING INSTRUCTIONS
STOVES MUST BE FITTED BY APPROVED, QUALIFIED AND
COMPETENT INSTALLERS
PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER
Penman Stoves operate at very high temperatures. All persons
including children and the infirm should be warned of this and not
allowed to touch any surfaces whilst in use. The operator must use
the glove provided.
www.penmancollection.com
VEGA EDGE SERIES INSTRUCTION – REV.D – JULY 2017
1

Advertisement

loading

Summary of Contents for Penman Collection VEGA 100

  • Page 1 VEGA 100 - VEGA 200 - VEGA 200SL MULTI FUEL STOVES APPROVED - CONFORMING TO EN13240:2001 and EN13240 A2:2004 INSTALLATION AND OPERATING INSTRUCTIONS STOVES MUST BE FITTED BY APPROVED, QUALIFIED AND COMPETENT INSTALLERS PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER Penman Stoves operate at very high temperatures.
  • Page 2: Table Of Contents

    CONTENTS STOVE CONTROLS, OUTPUT & EFFICIENCY PAGE 03 COMPONENT PARTS PAGE 04 INSTALLATION PAGE 05 OPERATION PAGE 10 GENRAL MAINTENANCE PAGE 16 SAFETY NOTES & TROUBLESHOOTING PAGE 18 STOVE ACCESSORIES PAGE 21...
  • Page 3 YOUR STOVE, OPERATING CONTROLS, OUTPUT AND EFFICIENCY VEGA EDGE 100 40mm 543mm 385mm 420mm 114mm 364mm VEGA EDGE 200 48mm 594mm 501mm 454mm 144mm 393mm VEGA EDGE 200SL 48mm 594mm 501mm 454mm 114mm 333mm VEGA EDGE 100 VEGA EDGE 200 VEGA EDGE 200SL WOOD ANTHRACITE...
  • Page 4: Component Parts

    COMPONENT PARTS Many spare parts are stocked – please refer to your retailer or supplier if you require any replacement parts. Please only use components made specifically for your stove. ITEM DESCRIPTION ITEM DESCRIPTION Left fire brick Riddling mechanism Glass panel 4 x stove legs Front bar Outer grate...
  • Page 5 INSTALLATION, OPERATION AND MAINTENANCE IMPORTANT: THIS APPLIANCE MUST BE INSTALLED BY A COMPETENT PERSON AND THE INSTALLATION MUST COMPLY WITH BS8303 – CODE OF PRACTICE FOR INSTALLATION OF DOMESTIC HEATING AND COOKING APPLIANCES BURNING SOLID MINERAL FUEL, NATIONAL BUILDING REGULATIONS, LOCAL BY-LAWS AND STANDARDS AND THE REQUIREMENTS OF THE HEALTH AND SAFETY AT WORK ACT - IN PARTICULAR: HANDLING –...
  • Page 6: Installation

    INSTALLATION Once the installation is complete, the installer must advise the householder on the correct use of the stove and warn them to use only the recommended fuels listed in this document. The installer must also advise the householder on the actions to be taken should smoke or fumes be emitted from the stove.
  • Page 7 The chimney must be swept before connection to the stove and swept every twelve months thereafter. It is recommended that your chimney is swept every six months. An existing fireplace opening can be modified to accommodate the stove. The following pages identify some typical installation scenarios and provides the necessary specific installation information for your new stove.
  • Page 8 Typical Installation for Inglenook Typical Installation Into In-filled Fireplaces – rear flue – Side View Masonry Fireplaces SPECIFIC INSTALLATION INFORMATION Legs Remove the legs from inside the stove. Carefully lay the stove on its back and using the screws provided fit the legs in place. Carefully set the stove upright and check that all internal components are correctly positioned.
  • Page 9 The stove can be recessed into a suitably sized fireplace built from non- combustible materials, but a permanent free air gap of at least 100mm should be left around the sides and top to obtain maximum heat output and for access to the rear of the stove.
  • Page 10 Flues With a Flue Draft Stabiliser Vega Edge 100 & Vega Edge 200SL - When installing with a flue draft stabiliser into houses built before 2008, at least 1500mm additional means of permanent ventilation direct to outside is required. Houses built after this date will require additional means of permanent ventilation direct to outside of at least 4250 .
  • Page 11: Operation

    OPERATION ALWAYS OPEN THE STOVE DOOR SLOWLY AND ALWAYS USE THE GLOVE Primary Air Primary air is controlled via the sliding vent in the bottom of the door. This provides an air draught to the bed of the fire. Slide right to open and left to close.
  • Page 12 First, load the fire with starting fuel i.e. paper, dry kindling timber (about the thickness of your thumb) and/or firelighters in the mode chosen, either wood or coal products. It is normal to see smoke come from the open stove door at this stage.
  • Page 13 primary air control fully closed and the secondary air control about half to two- thirds closed. Logs can be up to 300mm or 12” long. Do not overload. Of course, best burning depends on the quality of wood, draft and stove settings, so please do experiment to find your own best settings and the best position on your Stove Thermometer.
  • Page 14 through the fire bed and allowing the fire to burn over the whole grate. The riddling knob is located on the right hand side of the stove. The supplied stove tool must be used to turn this knob. Placing the ‘spanner’ end of the tool over the knob, rotate the tool clockwise and anti-clockwise –...
  • Page 15 The Vega Edge 100, Vega Edge 200 & Vega Edge 200SL are designed to be operated with the door closed, except for refuelling. Not only is it unsafe to operate with the door open but the appliance efficiency will be significantly reduced and excess smoke can occur.
  • Page 16: Genral Maintenance

    Fuel overloading The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke. Operation with door left open Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open except as directed in the instructions.
  • Page 17 Inner Grate Removal and Replacement Remove the ash pan and detach the riddling arm from the underside of the circular inner grate. Lift the inner grate vertically and manoeuvre it out of the stove. When replacing, ensure the riddling arm is re-connected to the inner grate.
  • Page 18: Safety Notes & Troubleshooting

    Safety Notes and Troubleshooting IT IS ESSENTIAL AND REQUIRED BY BUILDING REGULATIONS THAT A CO ALARM IS INSTALLED IN THE SAME ROOM AS THIS APPLIANCE. Fires Can Be Dangerous Always use a fire guard to BS 8423:2002, Fireguards for Use With Solid Fuel Appliances, in the presence of children, the elderly or the infirm.
  • Page 19 3. Check for a flue blockage and clean if required. Do not attempt to relight the fire until the cause has been identified and corrected. If necessary, seek professional advice. These situations are very dangerous and must NOT be tolerated. A list of Qualified Engineers is available from UK Solid Fuel Association R.
  • Page 20 Dirty Glass Nearly always caused by poor fuel quality – check the moisture content of the wood you are burning with a Penman moisture meter. Fire burning too low, open the air vents on the stove to create a hot fire, this may ‘burn’...
  • Page 21: Stove Accessories

    STOVE ACCESSORIES The following is a list of stove accessories your retailer will be able to supply:  Penman matching graphite high temperature paint  Stove Glass Cleaner  Spare Rope  Rope Seal Adhesive  CO Detector  Penman Stove Fan ...
  • Page 22 TECHNICAL FICHE 1 SUPPLIER NAME OR TRADEMARK PERCY DOUGHTY 2 MODEL IDENTIFIER VEGA EDGE 100 3 ENERGY CLASS 4 DIRECT HEAT OUTPUT 4.9kW 5 INDIRECT HEAT OUTPUT 6 ENERGY EFFICIENCY INDEX 101.0% 7 ENERGY EFFICIENCY AT NOMINAL HEAT OUTPUT 76.0% 8 SPECIFIC PRECAUTIONS SEE MANUAL 1 SUPPLIER NAME OR TRADEMARK...
  • Page 24 Brought to you by Percy Doughty & Co Imperial Point, Express Trading Estate, Stone Hill Road, Farnworth, Bolton. BL4 9TN 01204 868 550 www.penmancollection.co.uk...

This manual is also suitable for:

Vega 200Vega 200sl