  • Page 1 INSTALLATION INSTRUCTIONS VEGA C7 CONVENTIONAL FLUE GAS STOVE VC7 - REV A - 08/17...
  • Page 2 CONTENTS 1.0 USER INSTRUCTIONS - REMOTE CONTROL Page 3 General Manual transmitter Screen setup Setting the time Setting the timer: P1 and P2 (thermostat version only) Igniting the flame (remote control) Possible error messages Setting the flame height / extinguishing the flame Switching the unit off 1.10 Inserting and replacing batteries 2.0 USER INSTRUCTIONS - MANUAL CONTROL...
  • Page 3: General

    1.0 USER INSTRUCTIONS - REMOTE CONTROL General  The unit is operated using a radio-controlled remote control. This consists of a manual transmitter and a receiver. The receiver is connected to the gas control block.  The receiver and the gas control block are located behind the hinged panel on the front of the stove. ...
  • Page 4: Igniting The Flame (Remote Control

    1.0 USER INSTRUCTIONS - REMOTE CONTROL Igniting the flame (remote control)  Open the gas shut-off cock that has been installed in the gas pipe to the unit.  Press the “O I” switch on the gas control block to the “I” position. ...
  • Page 5 1.0 USER INSTRUCTIONS - REMOTE CONTROL 1.10 Inserting and replacing the batteries The manual transmitter and receiver batteries have a life span of approximately one year. The use of alkaline batteries is recommended. The batteries need to be replaced when: 1.
  • Page 6: Igniting The Fire

    2.0 USER INSTRUCTIONS - MANUAL CONTROL The unit may be operated by hand if there is a defect in the remote control. To do so, the ignite (piezo) cable of the receiver must first be removed and carefully slid into the piezo connector on the gas control block. Small metal circle for Manual ignition Main valve knob Piëzo Ignitter (Manual)
  • Page 7: Chimney Preparation

    3.0 INSTALLATION INSTRUCTIONS NOTE: The installation should only be performed by an authorized gas fitter. General information  The gas fireplace must be installed, connected and inspected by a qualified fitter, according to national, regional, and local standards and regulations. Failure to install the appliance correctly could lead to prosecution.
  • Page 8: Installation Of The Flue Liner

    4.0 POSITIONING THE APPLIANCE Installation of the flue liner For optimum performance we recommend that the chimney is lined with a 100mm diameter stainless steel gas flue liner. Proprietary terminals must comply with BS715 or BS1289. Any terminal or termination must be positioned in accordance with BS5440 Part 1 to ensure that the products of combustion can be safely dispersed into the outside atmosphere.
  • Page 9 5.0 TECHNICAL DETAILS GV60 Gas valve type: Mertik GV60 Ignition: Remote control operation and Piezo ignition Gas connection: 3/8 "(External) Unit category: B11BS Pilot flame: SIT 3 flames Pilot gas adjustment Pressure regulator MAN knob Main valve knob Ignition connection Side inlet Thermocouple Thermocouple...
  • Page 10 6.0 INSTRUCTIONS FOR MERTIK MAXITROL GV60 GAS CONTROL IMPORTANT: Do not start up the unit if the window is not present or broken. Ensure that the fuel supplied to the unit is clean and free from particles and moisture. Before a gas supply pipe (new or existing) is connected to the main gas pipe at the gas meter and to the gas control block of the unit, clean and dry compressed air should been blown through it.
  • Page 11 7.0 GAS TECHNICAL DATA CATEGORY I2ELL I2E+ I3+/I3B/P GAS TYPE G20/25 G20/25 G30/31 G20/25 PREPRESSURE MBAR 30/37/50 28-30/37/50 BURNERPRESSURE MBAR 15.53 12.45 10.65 10.65 29.5/36/36 27-29/36/36 10.65 INJECTOR SIZE Ø INPUT HI 6.18 5.55 6.23 6.23 6.26 6.26 6.23 INPUT 6.86 6.16 6.78...
  • Page 12 8.0 TROUBLESHOOTING FLOW CHART - MERTIK GV60 ACTION POSSIBLE PROBLEM/CAUSE SOLUTION Option: wall switch START: Bent pin on switch, or cable not Straighten pin, replace wall press ON button > wall switch operating properly. switch or cable. works. Manual transmitter START: press Manual transmitter battery low.
  • Page 13 8.0 TROUBLESHOOTING FLOW CHART - MERTIK GV60 ACTION POSSIBLE PROBLEM/CAUSE SOLUTION Ignition components not operating Check connection between cable & IGN properly. electrode. Check IGN electrode spark gap. Check IGN electrode for discharge to ground (break in ceramic). Check IGN cable for damage Continuous spark Increase distance between IGN cable and all metal parts.
  • Page 14 8.0 TROUBLESHOOTING FLOW CHART - MERTIK GV60 POSSIBLE PROBLEM/ ACTION SOLUTION CAUSE Resistance in thermo current Check cables and connections circuit too high. in thermo current circuit. Solenoid drops Not enough heat on Check position of pilot to (audible click) thermocouple.
  • Page 15 9.0 PROBLEMS AND POSSIBLE SOLUTIONS NOTE: Please first check if all guidelines were followed before attempting to solve any problems with the unit. IMPORTANT: Solving problems with your unit, whether gas related or electrical, must always be performed by a qualified technician. SYMPTOM ACTION TO BE TAKEN The pilot flame will not light...
  • Page 16 APPENDIX 1 - DIMENSIONAL DRAWINGS PRODUCT DIMENSIONS FLUE DIAMETER: 100mm GAS LINER / 125MM DECORATIVE SLEEVE PIPE INSTALLATION DIMENSIONS The stove must be located at least 280mm from any combustible materials. A combustible shelf may be fitted over the appliance: up to a depth of 150mm there must be a minimum 280mm clearance above the top of the stove.
  • Page 17 APPENDIX 2 - PREPARATION AND INSTALLATION NOTE: Some models may feature hexagonal nuts instead of wingnuts. In this scenario a suitable socket wrench or spanner can be used to tighten/loosen them. PAGE 17...
  • Page 18 APPENDIX 3 - CERAMIC LOG SET PLACEMENT NOTE: When installing the log set and the various glowing materials and accessories, the following must be taken into account: 1: No glowing material should be placed on or near the pilot burner. 2: Ensure that no ceramic material can fall on to the glass seals as this can damage the glass.
  • Page 19 APPENDIX 3 - CERAMIC LOG SET PLACEMENT PAGE 19...
  • Page 20 Brought to you by Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN Tel: 01204 868 550 Fax: 01204 868 551 Email: sales@percydoughty.com www.visionfires.co.uk...

Table of Contents