Manual Operation

Choose from two Manual Watering options:
Water All Zones Now
g

Turn the dial to AUTO RUN.
"
"
Press the WATER ALL ZONES NOW button to start water-
ing.
Screen displays which zone is being watered and the number of
minutes remaining for that zone.
To stop watering the active zone and skip to next zone, press the
WATER ALL ZONES NOW button again.
To stop manual watering, turn the dial to OFF, wait until
g

watering is stopped and then back to AUTO RUN.

Troubleshooting

Watering Issues

Problem
Automatic and manual cycles do
not begin watering.
Watering cycles do not shut off.

Electrical Issues

Problem
LCD Display is blank.
No red LED light on transformer
(indoor only).
LCD Display is "frozen" and timer
will not accept programming.
Valve short error message on
LCD display.
7
7
SST User Manual
SST user manual (EN) web.indd 7
Zone
Minutes
Remaining
Possible Cause
Water source not supplying water.
Wires not properly connected.
Wires damaged or corroded.
Dial not set to AUTO RUN position.
Date and/or Time is not set correctly.
An installed Rain Sensor may be
activated.
If no Rain Sensor is installed, the jumper
wire may be damaged or missing.
An electrical surge may have damaged
the timer's electronics.
Debris trapped in valve.
Possible Cause
Timer is not receiving power.
Blown transformer.
An electrical surge may have damaged
the timer's electronics.
Wires damaged or corroded.
Water 1 Zone Now
g

Turn the dial to select a ZONE.
"
"
Press the WATER 1 ZONE NOW button to start watering
(default run time of 10 minutes).
"
"
Press the UP/DOWN arrow keys to adjust the run time.
To stop manual watering, turn dial to OFF, wait until water-
g

ing is stopped, and then turn dial to AUTO RUN, or press the
Water 1 Zone Now button a second time.
Possible Solution
Verify the main water and all supply lines are open and operating properly.
Verify field wires are connected properly including the timer, master valve (or pump start
relay) and any spliced connections.
Check field wiring for damage and replace if necessary. Check all connections and replace
with watertight connectors as needed.
Turn the dial to set date and set time and use UP/Down arrows to set correct date and time.
Enter the current Date and Time on the controller.
Operation will resume when sensor dries out. To test operation, disconnect the Sensor and
connect a jumper wire between the Rain Sensor terminals.
Connect the two yellow Rain Sensor terminals with a short length of 14 to 18 gauge jumper
wire.
Disconnect power to the timer for 3 minutes, press the reset button, then turn back on. If
there is no damage, the timer will accept programming and resume normal operation.
Flush the valve by temporarily opening the bleed-screw and re-tighten.
Possible Solution
Verify the power cord is connected and securely plugged in (indoor).
Verify the transformer is wired correctly and the circuit breaker is on (outdoor).
Replace transformer.
Disconnect power to the timer for 3 minutes, press the reset button, then turn back on. If
there is no damage, the timer will accept programming and resume normal operation.
Check the indicated zone wiring for damage and replace if necessary. Check all connections
and replace with watertight connectors as needed.
Zone
Minutes
Remaining
10/11/2016 8:17:29 PM