8-3. Combination of external input and output

By combining the function setting of the indoor unit, you can select various combinations of func-
tions.
Combination examples of external input and output are as follows:
Mode
Function setting
0
1—8
60—01 to 60—08
9
10
11
NOTE: Input of Operation/Stop depends on the setting of function setting 46.
• 00: Operation/Stop mode 1 (R.C. enabled)
• 01: (Setting prohibited)
• 02: Forced stop
• 03: Operation/Stop mode 2 (R.C. disabled)
¢ Input signal type
• Indoor unit
Input signal type is only "Edge".
8-3. Combination of external input and output
60—00
60—09
60—10
60—11
Edge
External input
Terminal
Operation/Stop
(Setting prohibited)
Operation/Stop
Operation/Stop
Operation/Stop
- 35 -
External output
CN47
Error status
Indoor unit fan operation status
External heater output
8. External input and output