Page 1
OPERATOR MANUAL PGA TOUR POWER MODULE & SOLAR SKIRT P/N 50-000335 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Part Number: 21-0202306 October 2023 Solar Stik ® Inc.
Transportation ........... 31 October 2023 Solar Stik ®...
Page 3
Battery SDS..........43 ABOUT SOLAR STIK, INC.
Page 4
Table 2. Port and Load Limits ............................25 Table 3. Symptoms and Solutions for Power Module Issues ..................33 Table 4. In-storage Preventive Maintenance Checks and Services ................35 Revision History Section Page(s) Description Date First Published 7 Oct 2023 October 2023 Solar Stik ® Inc.
The Power Module is not eld serviceable beyond simple preventive maintenance. Do not attempt to ® open or service the unit. If repair is needed, it must be returned to Solar Stik , Inc. for service, or contact your eld service representative (FSR).
Since the use of this manual and the conditions or methods of operation, use, and maintenance of this product are beyond the control of Solar Stik, this company does not assume responsibility and expressly disclaims liability for loss, damage, or expense—whether direct, indirect, consequential, or incidental—arising out of or in any way connected with such operation, use, or maintenance.
SKIN CONTACT: Remove contaminated clothing and ush affected areas with plenty of water for at least 15 minutes. Wash skin with soap and water. If skin irritation persists, call for medical attention. INHALATION: Move to fresh air and seek immediate medical attention. Obtain medical advice. October 2023 Solar Stik ® Inc.
WARNING Only CO (Carbon Dioxide) re extinguishers should be used with Solar Stik equipment. Using the Fire Extinguisher When using the extinguisher on a re, remember PASS: Pull the pin. Aim the nozzle or hose at the base of the re from a safe distance.
Operator Manual for PGA Tour Power Module & Solar Skirt Environmental and Handling Precautions All Solar Stik components are ruggedized, yet there are a few things the operator can do to prevent failures and prolong the operational life of the product.
Figure 1. 24VDC PGA Power Module Adherence to operation and safety protocols will yield optimal performance from the Power Module for many years. Procedures for operation, preventive care and maintenance, and troubleshooting are all in this manual. October 2023 Solar Stik ® Inc.
• Each panel is rated at 160 W, 8.4 A, 58 V at standard test conditions (STC), therefore power generation is dependent on orientation • Silent operation, minimal footprint, ease of use and low maintenance P/N 11-100092 Figure 2. Solar Skirt October 2023 Solar Stik ® Inc.
Operator Manual for PGA Tour Power Module & Solar Skirt Equipment Description Air Intake Cable Pass-through Figure 3. 24VDC PGA Power Module (front) Figure 4. 24VDC PGA Power Module (back) October 2023 Solar Stik ® Inc.
Figure 6. Radar connector on (left), Solar connector on Solar Leash (middle) and Donor connector (right) Air Intake Air Exhaust Figure 8. 24VDC PGA Power Module (left side) Figure 7. 24VDC PGA Power Module (right side) October 2023 Solar Stik ® Inc.
15 W Radars (x2) Output Only 22 VDC 200 W Camera ports (x3): Pan & Tilt Output Only 22 VDC 110 W Switch 52 VDC 240 W Donor Output Output Only 48 VDC 600 W October 2023 Solar Stik ® Inc.
Continue to attach the Solar Skirt by zipping the three panels together. Connect the panel cables to the Solar Leash (Figure 9). Figure 9. Solar Leash Figure 10. Solar Skirt October 2023 Solar Stik ® Inc.
E. USB C Accessory Power Only 5V, 3A F. Cable Passthrough G. Camera Connectors H. E Display I. Clear window for viewing internal communication operations J. AP and Radar ports K. Breaker Status LEDs L. Fiber optic connectors October 2023 Solar Stik ® Inc.
The Power Module I-Plate provides setup and a quick-start guide for modes of operation. This guide is located on the inside lid of the Power Module (Figure 11) Figure 12. 24VDC PGA Tour Power Module I-Plate October 2023 Solar Stik ® Inc.
LED Circuit activity indicator Circuit breaker location DC bus circuit AC input Solar input Figure 13. Power ow from a top-down view of the interior of the Power Module October 2023 Solar Stik ® Inc.
• Allows connection of a generator or grid source for load support. Battery will serve as back-up power for critical loads during interruptions in AC source supply. Load Grid Loads Figure 16. Using the Power Module in UPS Mode October 2023 Solar Stik ® Inc.
The Power Module battery can be charged using 90-260 VAC input. While the System can accept a certain range of power, the universal input cable provided by Solar Stik is a 120 VAC locking cable and is compatible with North American 120 V, 60 hz power.
The PV array will provide 8.4 A up to 57.7 V under standard operating testing conditions. This assumes the Solar Skirt is positioned to harvest maximum sunlight and exposed to ideal temperatures that allow the MPPT charger to perform at maximum ef ciency. October 2023 Solar Stik ® Inc.
Connect a Donor Power Module using a bayonet cable connected between the 24 VDC Donor OUT- PUT port of the Donor Module and the Solar/Donor INPUT port on a separate receiver PGA Power Module. AC Charging Solar Charging DC Charging Donor Charging Figure 18. Power Module charging ports October 2023 Solar Stik ® Inc.
Battery State of Charge Battery State of Health Time Date Power Module/ Battery serial number battery net current (+) = net charging Battery/Bus voltage (-) = net discharging Figure 19. Power Module E Display October 2023 Solar Stik ® Inc.
2. Check the battery status. The Power Module Battery Status is displayed on the E Display (Figure 21). The E Display is programmed to auto refresh every three minutes. Figure 20. Power Figure 21. Power Module Battery Power Figure 22. E Display Module Battery Switch Breaker October 2023 Solar Stik ® Inc.
Two Power Modules can be connected directly to the Inter-Connect ports of the Power Module using Inter-Connect cables (Figure 232). Inter-Connect to Inter-Connect Figure 23. Methods for connecting additional storage capacity to the Power Module October 2023 Solar Stik ® Inc.
If a Power Module is “expanded” by adding another 24VDC PGA Power Module, both Power Modules will display accurate information in regards to their individual System. When two (2) Power Modules are connected at the Inter-Connect port, the batteries should behave as a single battery. October 2023 Solar Stik ® Inc.
• Shade the Power Module from exposure to direct sunlight to minimize solar loading and the resulting derating of power. • Keep the air intake/cooling fan lters clean to maximize air ow. Check/clean the lters more frequently when the operating environment is dusty. October 2023 Solar Stik ® Inc.
3. Disconnect the Power Module from all loads and power sources. 4. Examine and clean the exterior and ports. Close port covers. October 2023 Solar Stik ® Inc.
DTR. Refresher training IAW Service/Agency policy is required for all levels of HAZMAT training. For detailed information on all aspects of Transport for the Power Module, see the “Packaging, Handling, Storage & Transportation (PHS&T) and Disposal Information Sheet for the 24VDC Li Power Module 2400”. October 2023 Solar Stik ® Inc.
Only” label. Packages must also be marked with Proper Shipping Name (UN3481 Lithium Ion Batteries Contained in Equipment) and Shipper and Consignee addresses. • Shipper’s Declaration for Dangerous Goods. Not required, but may be requested by your shipper. October 2023 Solar Stik ® Inc.
2. Close lid and allow Power Module to cool 2. The E display overheated/ down. Shade the Power Module. Prevent direct sunlight exposure exposure to sun. 3. Power Module battery dead 3. Charge the Power Module battery. October 2023 Solar Stik ® Inc.
If dew is infrequent in the service environment, check the interior of the Power Module every third month and dry the interior as necessary. If water has condensed on interior parts, dry them completely before returning them to service. October 2023 Solar Stik ® Inc.
2. Clean excessive dust or inspection damaged, contact dirt accumulation from the of Power Solar Stik Technical exterior and ports. Module Support for advice on how to proceed. 3. Close all unused port covers.
• These lters must be checked and cleaned more frequently when operating in windy, dusty environments. • Replace the lters immediately when they become degraded, cannot be cleaned or restrict air ow in any way. To obtain replacement lters contact Solar Stik. Filter part number 14-1000071 October 2023 Solar Stik ®...
(3) Camera Connectors (customer supplied) (1) USB C 5 V, 3 A total (1) In/Out Inter-connect Port 24 VDC, 50 A Inputs/ (Deltran 224-0061-BK) Output(s) (1) USB A 5 V, 2.1 A total Raspberry Pi Data October 2023 Solar Stik ® Inc.
Input Current Internally limited to: 29 A Output Voltage Setpoint (adjustable) 43 V to 53 V Output Power Rating 600 W Output Current 12.5 A Output Fuse 15 A Max Output Ripple 0.25 Vrms Switching Freguency 54 KHz October 2023 Solar Stik ® Inc.
57.7 V Optimum Operating Current 8.4 A Open Circuit Voltage 69.2 V Short Circuit Current 9.0 A Solar Cell Ef ciency (%) >24.30% Number of Solar Cells / Panel Nominal Operating Protection 43 +/-2 C October 2023 Solar Stik ® Inc.
26 x 20 x 14 in (66 x 50.8 x 35.5 cm) Solar Skirt Weights and Dimensions Weight 39 lb. (17.7 kg) Dimensions 69 in base x 67.8 in height (175.3 x 172.3 cm) October 2023 Solar Stik ® Inc.
All of the individual Solar Stik components that operate in these categories utilize a unique connection architecture, know as the Inter-Connect Circuit. The Inter-Connect Circuit is the skeletal backbone of the Solar Stik System’s DC power network. It uses a simple, polarized, locking connection that is common throughout the architecture. All Solar Stik power management, energy storage, and power generation components are compatible with the Inter-Connect Circuit.
Page 41
50 A maximum current • 24 VDC connection only • Mechanically “locks” into place • Rotate knob clockwise to lock, • counterclockwise to release Can be repaired or modi ed in the eld • October 2023 Solar Stik ® Inc.
• hands-on deployment of actual systems to enhance student understanding. Solar Stik Training Courses are tailored to the speci c needs of the students. To schedule Solar Stik Training or to learn more about the curriculum, please contact us. Contact Technical Support Line 800-793-4364 Ext.
Need help?
Do you have a question about the 50-000335 and is the answer not in the manual?
Questions and answers